4. TROUBLESHOOTING
PROBLEM
PROBABLE CAUSE
PROBABLE SOLUTION
No flow.
A. No water supply.
A. Turn on water supply.
B. Blocked water filter.
B. Clear water filter (not supplied).
C. Pressure switch malfunction.
D. Strainer screen plugged.
C. Contact dealer.
D. Clean or replace strainer screen.
Flow to showerhead only.
A. No power to unit.
A. Turn on power at circuit breaker.
B. Transformer malfunction.
B. Contact dealer.
C. Solenoid malfunction.
C. Contact dealer.
Poor flow to sheetflow.
A. Blocked water filter.
A. Clear water filter (not supplied).
B. Low water pressure.
B. Provide 40 p.s.i. (2.8kg/cm
)
minimum static water pressure.
C. Too many outlets selected.
D. Strainer screen plugged.
C. Sheetflow performance is optimum
when only sheetflow is selected.
D. Clean or replace strainer screen.
Poor flow to other outlets.
A. Blocked water filter.
A. Clear water filter (not supplied).
B. Low water pressure.
C. Strainer screen plugged.
B. Provide 40 p.s.i. (2.8kg/cm
)
minimum static water pressure.
C. Clean or replace strainer screen.
In the U.S.A., call 1-800-4-KOHLER
In Mexico, call 001-877-680-1310
In Canada, call 1-800-964-5590