2. Install the Components
Prepare the Housing
Position the housing so the back of the leak shield is facing
toward you.
Apply a bead of silicone sealant in the groove around the
perimeter of the housing.
Do not apply silicone sealant in or
near the weep hole.
Allow the silicone sealant to cure.
Install the Components
Position the housing with the sealant side toward the rough
opening and the narrow end of the housing facing downward.
Guide the housing with leak shield over the street elbow and
through the center of the leak shield.
Press the housing firmly against the finished wall.
Thread the adapter onto the nipple using the provided 11 mm
hex bit, 11 mm or 7/16
″
socket, extension, and socket wrench.
Use masking tape to hold the bit in place, as the bit could fall off
and damage the product.
Install the Waterway
Press the waterway into place over the adapter.
Waterway
Leak Shield
Housing
Slot
Finished Wall
Adapter
Weep Hole
Apply silicone sealant.
Double
Ribs
1046519-2-B