background image

7. Use a vacuum cleaner to remove dust and dirt from the

filter.

8. Reinstall the filter assembly.

9. Turn on the all-pole switch.
10. Press the "+" for 2 seconds in the Activated mode(Page

13) to reset the filter cleaning indication.

7.

8.

9.
10.

P13

+

2

IMPORTANT CONSUMER INFORMATION

1. When AC power unit is connected to 220V AC power

supply, corresponding protective measures should be
taken.

2. Please confirm no water penetration at the connection area

of AC wire, and the connection area is not easy to be
affected by damp.

3. The head AC power supply must be protected with

appropriate fuse.

4. Please confirm the AC power supply should be shut off

before maintaining the products with AC power related.

5. All electrical connection must be compliance with related

regulation and codes.

6. All installation staff should be well familiar with installation

instruction.

Notice: Troubleshooting needs to be done by
professional of KOHLER CHINA. Users are not suggested
to do this without help. Please remember that the
checking and repairs done by users themselves could
easily cause damage to the machine or cause physical
harm to the person.

1.

220V

2.

3.

4.

5.

6.

-15-

1290505-T01-C

Summary of Contents for K-77283T-MZ

Page 1: ...Guide Underscore Bathroom Heater S450 S450 K 77315T MZ Air care K 77315T X MZ Cloud K 77283T MZ KOHLER CHINA INVESTMENT CO LTD NO 158 JIANG CHANG SAN ROAD JING AN DISTRICT SHANGHAI PRC POST CODE 2004...

Page 2: ...ies with GB 4706 1 2005 GB4706 23 2007 and GB 4706 27 2008 please leave instructions for the consumer GB 4706 1 2005 GB4706 23 2007 GB 4706 27 2008 WARNING Risk of electrical shock WARNING Risk of ele...

Page 3: ...ir Exhaust Pipe Clamp Air Outlet Window Keel M6 Nut M6 6 6 Spring Washer 6Washer 6 BTP4 8 Triangular Self Tapping Screw BTP4 8 Note Plaster or other ceiling opening dimension 450 X 290 mm 450 X 290 mm...

Page 4: ...MOTOR HOT MOTOR CAPACITOR CAPACITOR CAPACITOR CAPACITOR ALL POLE SWITCH OPTIONAL ALL POLE SWITCH OPTIONAL 220V 50Hz 220V 50Hz CN4 CN4 CN7 CN7 CN8 CN8 CN5 CN5 CN6 CN6 CN2 CN2 CN3 CN3 CN9 CN9 CN13 CN1 C...

Page 5: ...Outlet window installation Fix the air exhaust pipe to the outlet window on the wall with the clamp as the preparation of bathroom heater installation Seal the pipe and the outlet window with foaming...

Page 6: ...mm 275mm 1300mm 270mm C Packing List C 5 1285554 Decorated Plate X2 X2 1285555 Remote Control Only K 77315T MZ K 77315T X MZ K 77315T MZ K 77315T X MZ 1285542 Install Template 1285550 Ventilation Outl...

Page 7: ...0mm or above The power cord to the product shall have enough length for the installation The distance between the product and the air outlet window shall be 1000mm or lower Cut the screw rod M6 to sui...

Page 8: ...N Wiring Terminal 3 Installing the Main Body Method 1 integrated ceiling integrated ceiling should be 300 300 300 450 300 600 1 Disassembly the decorated plate around the position of the product inst...

Page 9: ...by 8 BTP4 8 screw 3 M6 4 8 BTP4 8 M6 Butterfly Nut M6 6 Washer 6 6 Spring Washer 6 M6 Nut M6 M6 Nut M6 BTP4 8 Triangular Self Tapping Screw BTP4 8 8 Suspender Cement Board Ceiling Surface Install temp...

Page 10: ...t Taper 1 100 1 50 BTP4 8 Triangular Self Tapping Screw BTP4 8 1 80 Ventilation Outlet Assy 80 Ventilation Outlet Assy Clamp Air Exhaust Pipe 80mm 7 Install the decorated plate and adjust the nut on t...

Page 11: ...ing position of the suspender as shown by the install template 2 Cement Board Suspender 10 2 Fix the ventilation outlet assy to the main body using the BTP4 8 self tapping screw 3 Fix the suspension b...

Page 12: ...e to install the remote controller shall not be easily splashed by water Choose a mounting location for the remote holder Drilling two holes with depth larger than 45mm on the wall by drill with a dia...

Page 13: ...mer down UP Timer up HEATER Turn on the heater mode FAN Turn on the fan mode DRY Turn on the hot cool dry clothes mode VENTILATION Turn on the ventilation long time vent mode 24 AIR FLOW Set the air f...

Page 14: ...ours the setting time cannot be changed E 6 10 6 6 10 6 6 10 6 6 10 6 2 10 2 24 24 TROUBLESHOOTING Problem Diagnosis Solution Bathroom Heater does not work The remote controller does not display The r...

Page 15: ...Do not use eradicator abrasive powder or oil acid or alkali liquid detergent to clean casing or air louver 3 Never try to put a small screw driver or any other object into the holes of air Louver fro...

Page 16: ...not easy to be affected by damp 3 The head AC power supply must be protected with appropriate fuse 4 Please confirm the AC power supply should be shut off before maintaining the products with AC powe...