2. Install the Overflow Ell
Attach the gasket to the overflow ell.
The tapered side should be facing out, and the thin edge should
be on top when the gasket is properly positioned.
Lubricate the O-rings on the overflow ell and insert the overflow
ell into the overflow tube.
Align the overflow ell with the overflow hole in the bath.
From inside the bath, thread two screws through the retainer
plate and into the two lower holes in the overflow ell.
Tighten the screws.
Tube
Gasket
Overflow
Ell
Retainer
Plate
Screws
Kohler Co.
5