background image

面遇到任何問題,務必請您與我們聯繫。

Product inlet hose

Product tee valve

 

Assorted screwdrivers

 

Screw

match with 10mm anchors

 

Expansion Bolt Kits

 

Fig.#1

  

TOOLS AND MATERIALS REQUIRED (Not supplied)

 

 

254mm adjustable wrench

Tape measure

Masking tape

  

Knife

 

 

VEIL  

 

BEFORE YOU BEGIN

 INSTALLATION INSTRUCTIONS

 INTELLIGENT 

TOILET

K-5401IN-0

Confirm the distance the water outlet connector away from the finished wall: upper the surface of finished wall by 

3mm and lower the surface of finished wall by 5mm

 

otherwise it may affect installation.

Recommend using the main inlet hose at least DN15mm to make sure the following request of water supply conditio ns.
Customer shall avoid any obvious pipe shrinkage or blockage from pipe installation or PPR pipe thermal fusion 

connection for better flushing effect. Ensure inlet water diameter after connection is greater than 15mm. 
Measure water conditions before  buying the product, there are two measure ways as following.

1

2

Confirm the rough in 305mm

it need reach to 292~350mm

otherwise it may affect installation.

Note

If combined with other faucets in the bathroom, make sure the water condition meets minimum requirement.

Use the hose and Tee valve of this toilet.

3 Make sure meet the following water supply condition request before installation. 

Simple way to measure water volume:

Prepare a bucket. Fully turn on the tee valve. Firstly flush three times and test. Fill the bucket with water into 

the bucket for 10 seconds. The mininum water volume is advised to be above 5.7L.

Pre-arrange enough space for toilet installation. Make sure it will not affect the opening and closing of the door.
When install the product in the room, a stop valve shall be installed in a close proximity. For emergency 

circumstances, the water inlet valve shall be stopped without using any tools; otherwise unexpected failure may 

cause the loss to the customer. 

These instructions contain important care, cleaning, and warranty information - please leave instructions for the

 

 

consumer.

We appreciate your commitment to Kohler quality. Pleas

 

 

 

 

e take a few minutes to review this manual before 

 

installation. If you encounter any installation or performan

 

 

ce problems, please don't hesitate to contact us.Thanks 

again for choosing Kohler Company. 

Please read the following instructions carefully and familiarize yourself with the required tools, materials, and 
installation sequences. Follow the section that pertain to your particular installation. This will help you avoid costly

 

 

 

mistakes. In addition to proper installation, please also read all operating and safety instructions. 

All information in the instructions is based upon the latest product information available at the time of publication. 

 

 

 

Kohler China reserves the right to make changes in product characteristics, packaging, or availability atany time
without notice.  

1373184-IN01-A

2

Kohler Co.

Summary of Contents for K-5401IN-0

Page 1: ...T K 5401IN 0 Kohler China Investment Co Ltd No 158 Jiangchangsan Road Jing An District Shanghai PRC Post Code 200436 Manufacturer Shanghai Kohler Electronics Ltd No 1955 Fengxiang Road Baoshan Area Shanghai PRC Post Code 200444 1373184 IN01 A ...

Page 2: ...et Fully turn on the tee valve Firstly flush three times and test Fill the bucket with water into the bucket for 10 seconds The mininum water volume is advised to be above 5 7L Pre arrange enough space for toilet installation Make sure it will not affect the opening and closing of the door When install the product in the room a stop valve shall be installed in a close proximity For emergency circu...

Page 3: ...e t y t i c a p a c y l p p u s r e t a w d e t a c i d e d e s u t s u m n o i t n e t t A flush three times and test The minimum dynamic pressure for the testing device is advised to be above 0 046Mpa 6 7 psi Observe all local plumbing and building codes Carefully inspect the new toilet for damage Water and electrical supplies may be wall mounted There is a wiring schematic on the inside of the ...

Page 4: ...ght of product Inlet water temp Operation Environment NOTE See Homeowner s Guide for detailed specifications of the bidet seat Fig 3 Kohler reserves the right to change marked dimensions without prior notice Remote control Unit mm 160 Finished Wall 438 900 533 100 150 250 Water Outlet Finished Floor 330 58 670 Tee valve G1 2 Need customer to purchase Bidet inlet hose G3 4 G1 2 Toilet inlet hose Te...

Page 5: ...urn it off Press Warm Wind button to start the warm wind function Press the button to enter Rear Wash mode Light sensing area Press the button to enter Front Wash mode Press it again to turn it off Press the button to turn off the night light function long tone hint Press the button to turn off the power long tone hint Press it again to turn it off Press it again to turn on short tone hint PREPARA...

Page 6: ...ted on the wall a GFCI or ELCB protected and water proof receptacle is required Fig 7 A INSTALLATION To Remove Existing Toilet Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old tank and bowl B Place an 800mmX800mm cushion on the floor take out the toilet from the carton...

Page 7: ...down the centerline on Front back left and right outside of toilet Make sure the toilet side mark symbol is align to the drain hole centerline on the finished floor Mark down the left and right holes C 1 Confirm the drain hole center and mark down the centerline perpendicular to the finished wall Fig 8 Unit mm 250 10 330 10 250 10 200 5 85 5 305 150 10 150 10 100 10 Kohler Co 7 1373184 IN01 A ...

Page 8: ...lectrical supply connect only to a a Class A Ground Fault Circuit Interrupter GFCI or Earth eakage Circuit Breaker ELCB NOTE This product is designed for installation with the electrical supply attached to the wall Both types are illustrated Refer to the dimensional information for your chosen installation Follow the dimensional information exactly when installing the hardwire electrical supply Si...

Page 9: ...en the trap way will not be properly aligned Make all adjustments gently reference the toilet side mark symbol and the drain hole centerline on the finished floor until the trapway is properly seated Use nut and washer to fasten the bolts and fix up the toilet CAUTION Risk of product damage Do not move the toilet after the trap way is properly seated to avoid the wax seal invalidated Change the wa...

Page 10: ...e B NOTE Please do not reuse the old hose K Connect the Water IMPORTANT The supplied hoses must be used for this installation Bidet inlet Valve B G1 2 Back view Toilet hose Toilet inlet Valve A G3 4 supply stop 250 10 330 10 100 10 150 10 Close by rotating the handle clockwise and open counterclockwise Handle of angle valve Tee valve Decorative cover Connect to grey water G3 4 Connect to tap water...

Page 11: ...s down left button for about 2 seconds then press down right button for about 3 seconds and again press down left button for about 6 seconds to complete water flushing M Caulk along the toilet bottom except for the side plates Finish installation by fixing the side plates Side plate two sides Fig 17 Fig 18 Kohler Co 11 1373184 IN01 A ...

Page 12: ...le Choose a mounting location for the remote holder that is easily accessible while sitting on the seat Drill two holes with depth larger than 45mm on the wall by drill with a diameter of 6mm in accordance with the position of screw holes on the remote control holder Install the expansion tube into the holes Peel off the release paper of the double sided tape at the back of holder Expansion pipe E...

Page 13: ...ing sound of the motor and bicker When the lighting stops flickering the self check is completed When it is used for the first time product will be in default stage Front Water temp mid Pressure mid Position level 3 Rear Water temp mid Pressure mid Position level 3 Spiral Water temp mid Pressure mid Pressure mid Seat temp mid Wind temp mid Night light On Energy saving mode On Function of auto cove...

Page 14: ...h In that case adjust the hoses G Flush again after this flushing in progress seated The wash mode when people are not Dryer fan stops in the process of may work even A Water failure B Tee valve for water supply is closed or not opened completely C Product is at standby mode D Not yet seated or current sitting posture unable to be sensed by the seat E Filter screen is blocked F Water pressure is i...

Page 15: ... toilet body Check the section of Communication between remote controller and this machine and connect the toilet and the remote controller Touch the screen of remote controller Sit near to the toilet or be seated Press Wake up key of remote controller A Replace by new battery B Reinstall properly C A The seat is covered by foreign matters or the seat is wet B The toilet cover is interfered by peo...

Page 16: ...le installing the toilet Thermalexpansion of hard setting material cement mortar will damage or crash the feet of toilet Kohler will not be responsible for any damage because of using hard setting material cement mortar for toilet installation WARNING Risk of product damage Do not throw into the toilet what that will cause the toilet to block such as newspapers and sanitary towel Do not bump the v...