6. Install the Vitreous Shell
WARNING: Risk of personal injury.
The vitreous shell weighs 105 lbs (36 kg). Use proper lifting
technique when handling the vitreous shell. Lift and position the vitreous shell with a partner.
CAUTION: Risk of product damage.
Do not set the shell down hard. Gently lift and move the shell if it
is not placed correctly. If handled carelessly, the shell may chip or break.
With assistance, carefully pick up the vitreous shell and slowly lower it over the tank.
Remove the cap from the capped elbow port.
Connect the bidet hose to the elbow.
Make sure the trapway in the vitreous shell seats fully in the outlet gasket. If the vitreous shell does
not sit evenly on the floor, the trapway may not be properly seated.
Adjust the vitreous shell as needed until the trapway is properly seated.
Reconnect the water supply hose to the water supply if it was disconnected.
Connect the Wires
CAUTION: Risk of personal injury.
Make sure the plug (if plug-in connection is used) and
receptacle are dry. If any moisture is present, allow the area to dry before plugging the unit in.
Remove the tape from the floor wires and toilet.
Connect the level switch and refill tube.
Connect the bidet wiring harness and pump wiring harness.
Vitreous
Tank
Collar
Bidet
Wiring Harness
Pump
Wiring Harness
Level Switch
Refill Tube