2. Install the Tank
CAUTION: Risk of property damage.
Do not rock or lift the tank after placement. The seal created
by the wax ring may be broken, resulting in leaking.
CAUTION: Risk of product damage.
Do not push down on any part of the tank assembly other than the
cylinder. Damage may occur.
Position the wax ring on the floor flange.
Remove the outlet gasket.
Align the tank over the floor flange and T-bolts.
Lower the tank onto the floor flange with the slots in the base of the tank aligned with the T-bolts.
Carefully align the tank on the centerline.
CAUTION: Risk of product damage.
Only apply downward pressure to the tank cylinder. Do not press
on the tank components other than the cylinder, or damage may occur.
Press down evenly on the rim of the cylinder to set the wax ring.
Reinstall the outlet gasket.
Press here on
cylinder.
Floor Flange
Tank
T-Bolts
Centerlines
Wax Ring
Outlet Gasket