IMPORTANT INSTRUCTIONS
READ AND SAVE FOR THE
CONSUMER
WARNING: Risk of scalding or other severe injury.
CAUTION: Risk of scalding hazard.
This device has been
calibrated at the factory to ensure a safe maximum water
temperature. Any variance in settings or water inlet
conditions from those used during factory calibration may
raise the discharge temperature above the safe limit, and may
present a scalding hazard.
•
Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
The installer is responsible for adjusting the maximum water
temperature of this valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the temperature adjustment
instructions in this document, in the United States please contact our
Customer Care Center at
1-800-4KOHLER.
Outside the U.S., please
contact your distributor.
IMPORTANT NOTICE:
Please fill in the blanks on the valve label and
below, in the NOTICE TO HOMEOWNERS box. Retain this guide for
future reference.
•
The valve is calibrated to 104°F (40°C) at the first stop position,
and the maximum temperature limit stop is positioned so the
outlet water temperature does not exceed 120°F (49°C).
•
Factory calibrated inlet conditions are:
Hot and cold water pressure = 43-1/2 psi (300 kPa)
Hot water supply temperature = 149°F (65°C)
Cold water supply temperature = 59°F (15°C)
•
If inlet conditions differ from those used during factory
calibration, it may be necessary to re-calibrate the valve after
installation.
The installer must check the mixed flow
temperature after installation, and adjust the valve as needed
according to the instructions.