Adjust the Hot Temperature Limit (cont.)
Using a thermometer, check the temperature of the water.
Turn the valve stem clockwise until the water temperature
reaches 120°F (49°C).
Reinstall the spline adapter with the adapter tab positioned flush
with the hot temperature limit stop on the cartridge.
Using the volume control valve (not shown), turn off the water.
Hot Temperature
Limit Stop
Adapter Tab
Hot Temperature
Limit Stop
Adapter Tab
Spline Adapter
Valve Stem
Kohler Co.
19
1145568-2-A
Summary of Contents for K-2972