Troubleshooting (cont.)
Symptoms
Probable Cause/Recommended Action
3.
No flow from shower
control water outlet.
A.
Filter screens are blocked. Clear filter
screens.
B.
Hot or cold supply failure. Replace
the supply valve.
C.
Flow control cartridge not working.
Check and replace if necessary.
D.
Service stops are shut off. Rotate both
service stops clockwise until fully open.
4.
Blend temperature drift.
A.
Indicates operating conditions have
changed. No action is needed.
B.
Refer to symptom 2.
C.
Hot supply temperature fluctuation.
D.
Supply pressure fluctuation.
5.
Hot water in cold supply
or cold water in hot
supply.
A.
Indicates crossflow. Replace check
valve.
6.
Maximum blend
temperature setting too
hot or too cold.
A.
Indicates incorrect maximum
temperature setting; refer to the
″
Adjust
the Hot Temperature Limit
″
section.
B.
Refer to symptom 4.
C.
Refer to symptom 5.
7.
Water leaking from the
valve body.
A.
Seal(s) worn or damaged. Obtain
service kit and replace seal(s).
B.
If leaking from around the
temperature spindle, replace the
thermostatic cartridge.
8.
Flow knob or
temperature knob is stiff
to operate.
A.
Impaired free movement of internal
components. Replace the appropriate
cartridge.
B.
Supply pressures are too high. Fit
pressure reducing valve.
Warranty
KOHLER
®
Faucet Lifetime Limited Warranty
Kohler Co. warrants its Faucets* manufactured after January 1, 1997, to
be leak and drip free during normal residential use for as long as the
original consumer purchaser owns his or her home. If the Faucet
should leak or drip during normal use, Kohler Co. will, free of charge,
mail to the purchaser the cartridge necessary to put the Faucet in good
working condition. This warranty applies only to Kohler Faucets
Kohler Co.
25