Applicable product:
Drop-in rim style

K-1224P

Integral flange, left drain

K-1224P-L

Integral flange, right drain

K-1224P-R

Fixture*:
Bathing well:
Basin area, bottom

48

(121.9 cm) x 24

(61 cm)

Basin area, top

59

(149.9 cm) x 30

(76.2 cm)

Weight

110 lbs (49.9 kg)

To overflow:
Water depth

14

(35.6 cm)

Capacity

67 gal (253.6 L)

* Approximate measurements for comparison only.

Drop-in cutout dimensions:
64

(162.6 cm) x 34

(86.4 cm)

V

Hz

A

Pump: 1-speed

120

60

7.5

Minimum access panel

pump/control (required):

20

(50.8 cm) W x

15

(38.1 cm) H

Required Electrical Service

Dedicated circuit required, protected with a Class A

Ground-Fault Circuit-Interrupter (GFCI):
Pump/control

120 V, 15 A, 60 Hz

Notes

Install this product according to the installation guide.
Floor support under this product must provide for a minimum of

42 lbs/square foot (206 kg/square meter) loading.
The apron must be installed before the finished floor and wall

materials are installed.
If installing a rim-mount faucet, make sure there is no interference

with the drain overflow and circulating system before drilling any

holes. Consult local and national codes for minimum air gap

requirements if installing a spout on the faucet deck.
This fixture conforms to CSA B45 and ANSI Standard Z124.1.2. All

dimensions are nominal.

No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)
Recommended Faucet Area

Pump/Control Access
(If Apron Is Not Used)
20" (50.8 cm) W x
15" (38.1 cm) H

18-1/2"
(47 cm)

20"
(50.8 cm)

8-11/16" (22.1 cm)

1-11/16"
(4.3 cm)

3"
(7.6 cm)

2-7/8"
(7.3 cm)

1" (2.5 cm)

35-7/8" (91.1 cm)

3-1/2"
(8.9 cm)

18"
(45.7 cm)

66" (167.6 cm)

1-1/2" OD

1-1/4"
(3.2 cm)

1/2" (1.3 cm)
R. Max

Integral
Flange Detail

1-1/2"
(3.8 cm)

Drop-in Rim
Detail

K-1224-*

1014719-1-B

2

Kohler Co.

Summary of Contents for K-1224P

Page 1: ...mbers are for Mexico i e K 12345M Los números de productos seguidos de M corresponden a México Ej K 12345M Français page 3 Español página 4 USA Canada 1 800 4KOHLER México 001 800 456 4537 kohler com K 1224P K 1224P L K 1224P R 1014719 1 B 2009 Kohler Co ...

Page 2: ... this product must provide for a minimum of 42 lbs square foot 206 kg square meter loading The apron must be installed before the finished floor and wall materials are installed If installing a rim mount faucet make sure there is no interference with the drain overflow and circulating system before drilling any holes Consult local and national codes for minimum air gap requirements if installing a...

Page 3: ... sol sous ce produit doit pouvoir soutenir une charge minimale de 42 lbs pied carré 206 Kg m2 Le bandeau doit être installé avant d installer le sol fini et les matériaux du mur Lors de l installation d un robinet sur le rebord s assurer qu il n y ait pas d interférence avec le trop plein du drain et le système de circulation avant de percer des orifices Consulter les codes nationaux et locaux pou...

Page 4: ...soporte del piso debajo de este producto debe poder soportar una carga mínima de 42 lbs pie cuadrado 206 kg metro cuadrado El faldón debe instalarse antes que los materiales de acabado del piso y la pared En caso de instalar la grifería en el borde asegúrese de que no interfiera con el rebosadero de desagüe y el sistema de circulación antes de taladrar los orificios Consulte los códigos locales y ...