Optional Temperature Limiting Adjustment
If desired, use the following procedure to adjust the maximum water
temperature setting:
Remove the plug button.
Loosen the setscrew and remove the handle and bonnet.
Position the indexer to stop the valve stem at the desired
maximum temperature.
Turn the water on and rotate the valve stem to full hot to confirm
the setting.
Reinstall the bonnet and handle.
Tighten the setscrew.
Reinstall the plug button.
Lifetime Limited Warranty
Kohler Co. warrants its faucets manufactured after January 1, 1997, to
be leak and drip free during normal residential use for as long as the
original consumer purchaser owns his/her home. *If the faucet should
leak or drip during normal use, Kohler will, free of charge, mail to the
purchaser the cartridge necessary to put the faucet in good working
condition.
Kohler also warrants all other aspects of the faucet, except gold finish,
to be free of defects in material and workmanship during normal
Bonnet