6. Make Electrical Connections
DANGER: Risk of electric shock.
Connect the blower motor to a properly grounded,
grounding-type receptacle protected by Ground-Fault Circuit-Interrupters (GFCI’s) or Residual
Current Devices (RCD’s). Do not remove the plug grounding pins. Do not use grounding adapters.
NOTE:
The bath with airjets model number is printed on a label near the blower motor. This label also
identifies the electrical rating.
Your Kohler bath with airjets is equipped with a cord and plug. The blower motor has been wired
at the factory. A licensed electrician must install a dedicated GFCI-protected, 120 V, 15 A, grounded
outlet. Locate the outlet behind the bath and within 24
″
(61 cm) of the blower motor.
Plug the blower motor into this outlet.
Clean the area of all dust and debris.
Blower Motor
GFCI-Protected
Receptacle
Kohler Co.
9
1034591-2-F
Summary of Contents for K-1164
Page 46: ...1034591 2 F ...
Page 47: ...1034591 2 F ...