5. Install the Bath
Turn the bath shell rim-side down on saw horses.
Wrench tighten all connections and fittings on the drain to one quarter turn past hand-tight.
Reattach the bath apron to the bath shell. The edge of the bath apron must be positioned inside the
flange of the bath shell.
Secure the bath apron to the bath shell with screws at each corner of the bath.
Carefully lift the bath into place. Ensure the bath is aligned with the mounting bracket and the
drain tailpiece is aligned with the P-trap.
NOTE:
Use the tip of a flat-blade screwdriver to push the locking plate into the
″
locked
″
position.
Push the locking plate of each mounting bracket in toward the center of the bath with a flat-blade
screwdriver.
Push down on the bath rim with your hand to verify the bath does not move from side-to-side or
up and down. If the bath moves, the locking plate(s) is/are not in the
″
locked
″
position. Repeat the
above step, if necessary.
Locked Position
Unlocked Position
Push locking plate in
toward center of bath.
Locking Plate
Kohler Co.
7
1055344-2-A