7. Make Electrical Connections
WARNING: Risk of electric shock.
To reduce the risk of electrical shock, connect the pump and in-line
heater (if heater option included) to properly grounded, grounding-type receptacles protected by
Ground-Fault Circuit-Interrupters (GFCI’s). Do not remove the plugs’ grounding pins. Do not use
grounding adapters.
NOTE:
The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All of the heater wiring has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet.
Pump Wiring
NOTE:
The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control
has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A,
grounded outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool,
and within 24
″
(61 cm) of the pump.
Plug the pump into this outlet.
NOTE:
Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
If a K-1639 Timer Kit will be used, install it now according to the instructions packed.
In-Line Heater Wiring
″
H
″
Models:
The heater is equipped with a cord and plug. All wiring of the heater has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool, and within
24
″
(61 cm) of the heater.
Plug the heater into this outlet.
Bond in accordance
with applicable codes.
Install a GFCI-
protected 120 V, 15 A
grounded outlet.
Heater
Plug the pump
into this outlet.
Install second GFCI-
protected outlet for "H"
models for the in-line heater.
1012295-2-D
8
Kohler Co.
Summary of Contents for K-1109
Page 35: ...1012295 2 D ...