Troubleshooting Procedures (cont.)
Symptoms
Probable Causes
Recommended Action
C.
Air hose is pinched or kinked.
C.
Adjust hose to clear the
pinched/kinked area. If the
tubing is pinched/kinked and
cannot be readjusted, or no
noticeable pinch/kink is
apparent, poke a small hole in
the tubing with a tack and try
the system again.
D.
Part(s) of the push button
assembly is/are damaged.
D.
Replace the push button
assembly.
E.
Push button has grease in the
bleed area.
E.
Disassemble the push button
assembly and wipe away any
excess grease. Reassemble the
button and retry the system.
F.
Air hose is damaged.
F.
Replace the air hose.
G.
Motor/pump does not work.
G.
Rebuild or replace motor/pump.
2.
Motor starts, not all jets
are functioning.
A.
Jet is closed.
A.
Rotate jet trim ring
counterclockwise to open.
B.
Jet is not installed correctly.
B.
Reinstall jet; check for O-ring
damage.
C.
Jets are blocked.
C.
Remove blockage.
3.
Footbath stops
automatically before 18
minutes.
A.
The GFCI trips.
A.
Identify source of fault, and
correct.
B.
Suction is blocked.
B.
Remove obstruction.
C.
Jets are blocked.
C.
Remove blockage.
D.
Motor overheated and protection
device activated.
D.
Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
blockage and allow motor to
cool.
4.
Noisy operation.
A.
The pump banding straps have
not been cut.
A.
Using tin snips, cut the pump
banding straps.