background image

2

97444-2-

AA

 (-)

DO IT RIGHT! Use a Kohler Certified
Installer, (KCI), for the installation of your
Kohler Shower Door. Contact your
Kohler Distributor/Showroom or call
Kohler at 1-800-456-4537 for the KCI
nearest you.

Introduction

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. The Exploded Diagram of the Door on page13
will also provide a helpful reference when relating the
location of the various parts.

All information in these instructions is based on the
latest product information available at the time of
publication.  Kohler Co. reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.

IMPORTANT CONSUMER INFORMATION

LIMITED ONE-YEAR WARRANTY

Kohler plumbing fixtures and fittings are warranted free of manufacturing
defects.

Kohler Co. will, at its election, repair, replace, or make appropriate
adjustment where Kohler Co. inspection discloses any such defects
occurring in normal usage within one year after installation. Kohler Co.
is not responsible for installation costs.

To obtain warranty service, contact Kohler Co. either through your Dealer
or Plumbing Contractor or by writing Kohler Co., Att: Consumer Affairs
Department, Kohler, WI 53044 U.S.A.

IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY,
ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF
THIS WARRANTY. KOHLER CO. DISCLAIMS ANY RESPONSIBILITY
FOR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied warranty
lasts, or the exclusion or limitation of incidental or consequential
damages, so this limitation and exclusion may not apply to you. This
warranty gives you specific legal rights. You may also have rights which
vary from state to state.

This is our exclusive written warranty.

KOHLER CO., KOHLER, WISCONSIN 53044

BASIC TOOLS AND MATERIALS NEEDED

TOOLS

6 foot folding rule or measuring tape
Hacksaw with 32 teeth per inch blade
Miter box or square
Hammer
Electric drill
Drill bit-3/16

Masonry bit for ceramic tile-3/16

Fine file
Screwdriver-Phillips
Level
Pencil
Safety glasses
Caulking gun
Knife
Pliers

MATERIALS

Masking Tape
Silicone Sealant (RTV)

HOW TO CARE FOR YOUR DOOR

NEVER USE SCOURING POWDER, PADS OR SHARP
INSTRUMENTS ON METAL WORK OR GLASS PANELS.

The use of a squeegee following each shower is
recommended to eliminate water spots on the inside of the
glass panels.

An occasional wiping down with a mild detergent diluted in
water is all that is needed to keep the panels and anodized
aluminum parts looking new.

CAUTION: TEMPERED GLASS CANNOT BE CUT.

Summary of Contents for Focal 701263

Page 1: ...97444 2 AA...

Page 2: ...tor or by writing Kohler Co Att Consumer Affairs Department Kohler WI 53044 U S A IMPLIEDWARRANTIESINCLUDINGTHATOFMERCHANTABILITY ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THISWARRANTY KOHL...

Page 3: ...3 97444 2 AA 1 CAULK AND INSTALL SUB TRACK A If your style requires a sub track apply a bead of caulk to the underside of the sub track as shown B Install the sub track Sub Track Front Side Caulk Here...

Page 4: ...mes Secure the in line panel to the installed in line jamb with No 8 18 x 3 8 panhead screws Do not secure the opposite in line jamb now D Mark the bottom track location on the sub track and remove th...

Page 5: ...ide the in line panel into the installed in line jamb Fit an in line jamb over the opposite side of the in line panel IMPORTANT For some styles do not adjust and secure panel until L Jamb has been ins...

Page 6: ...ert plug Plug No 8 32 Nut L Jamb Front Side 7 INSTALL L JAMB TO IN LINE PANEL JAMB A Insert a pin through the hole of the bottom bracket with head of pin toward bottom track Place a washer down over t...

Page 7: ...BOTTOM TRACK SEAL A Measure from the front edge of the strike expander jamb to the edge of bottom bracket as shown B Cut the seal distance measured C Push the seal into the bottom track as shown D Tr...

Page 8: ...cate the block 1 4 less than measurement from A D Insert a No 8 18 x 1 2 panhead screw with a No 8 lockwasher through frame slot of the door panel top frame and into block screwport E Fasten the screw...

Page 9: ...racket hole and into the block hole E Loosen the block screws and slowly close door panel and slide blocks in top and bottom frames so that door closes with approximately 3 16 clearance from edge of s...

Page 10: ...d Screw 1 4 L Jamb Inside of Shower Door Panel Top Track 1 4 Bracket 13 INSTALLING WASHER AND SCREW NOTE It is necessary to install the No 8 cup washer and the No 8 32 x 5 16 undercut head screw to pr...

Page 11: ...rom the top of door C With a pair of pliers squeeze the edge of the T shaped slot at the top of door panel to hold the flat seal in place Flat Seal Pivot Side Frame T Shaped Slot 15 SEALING A Carefull...

Page 12: ...the groove on one side along the length of the door handle side frame as shown B Push the door handle cushion into the other groove along the length of the door handle frame and trim excess cushion wi...

Page 13: ...5 15 10 16 16 16 11 9 9 11 10 25 23 25 21 20 4 23 18 24 24 19 20 2 26 17 35 35 26 17 32 8 3 3 14 31 7 6 26 26 26 25 25 25 11 9 9 16 16 16 11 10 25 25 25 15 15 26 33 34 22 10 15 16 16 23 16 25 16 25 25...

Page 14: ...nhead Screw 11 17 Block 2 18 Top Bracket 1 19 Bottom Bracket 1 20 Pin 2 21 Bracket Plug 1 22 Nylon Washer 1 23 No 8 32 Nut 4 24 No 8 32 x 3 4 Panhead Screw 4 25 No 8 18 x 3 8 Panhead Screw 15 26 No 8...

Page 15: ...15 97444 2 AA...

Page 16: ...1999 Kohler Co 97444 2 AA...

Reviews: