background image

2

.

*

Sterilized water (refers to refers to the tap water containing hypochlorite generated by chlorine ions after ionization): 

Sterilized water generated during electrolysis working cycle eliminates 

bacteria on the nozzle surface. The antibacterial rate is more than 96%. (Perform test in accordance with GB /T 23131 when the content of chlorine ions in tap water is >24ppm. Different 

water quality might cause different sterilization effect. Electrolysis working cycle activation method refers to operation description. Testing lab: China household  electrical appliances 

testing institute.).

When unseated, press “One button sterilization” button on remote to activate UV sterilization function 

(details are shown in the diagram of remote control).
During sterilization process, if customer open cover and start use toilet, or presses STOP button on remote, 

UV sterilization function will be deactivated. 

3. Manual UV sterilization

Sterilized water*

Automatic energy saving function

Inlet water filtration

Deodorizer 

When energy saving set to ON status, product shall auto detect the idle hours and decrease the heating 
temperature to reach of energy saving purpose.
For details of automatic energy saving, refer to page 

9

.

1.

2.

4.

1. Product default factory setting is auto activate deodorizer function when detecting customer seated.
2. Refer to Remote Setting for how to switch over auto deodorization function.

When filter almost expires, orange LED keeps ON (as shown).
When filter has expired and require replacement, orange light blinks.

 

Orange and while LED blinks alternately indicate improper filter installation.

 

For filter exchange refer to page 

18

.

Purified water used for rear wash/spiral wash/front wash.

1.
2.
3.

* UV sterilization (refers to the ultraviolet sterilization generated by UV lamp): During UV working cycle, the bacteria on nozzle surface will be eliminated by irradiation. The antibacterial 

rate is more than 99%. (Measured after one UV working cycle, it was measured within 18mm×8mm irradiation area. Perform test in accordance with GB /T 23131 requirements, UV 

radiation zone was shown in the diagram, UV working cycle activation mode refers to users guide. Testing lab: China household electrical appliances testing institute.)

UV sterilization function*

1.UV function is used to sterilize the nozzle by UV.
2. Auto UV sterilization

When toilet is not in use for a long time, auto UV sterilization function will be activated and start sterilizing 

nozzle. No sterilization function shall be activated after this process in another 24hrs. 
During 

UV 

sterilization process, if customer open cover and start use toilet, or presses STOP button on 

remote, UV sterilization function will be deactivated. 
Auto UV sterilization function setting refer

s

 

to

 Page 

9

.

1413624-T01-B

16

Kohler Co.

Summary of Contents for EIR

Page 1: ...1955 200444 Homeowners Guide EIR INTELLIGENT TOILET English page 2 25 26 48 1413624 T01 B...

Page 2: ...d OPEN CLOSE ring OPEN CLOSE 12 Flushing your toilet 13 Auxiliary key function 15 UV sterilization function 16 Sterilized water 16 Auto energy saving function 16 Inlet water filtration 16 Deodorizatio...

Page 3: ...pipe connector is pulled or pressed with excessive force Important Risk of product damage The product may be damaged if the nozzle is applied with excessive force Important Risk of product damage The...

Page 4: ...is connected Prevent water splash on power plug only for models with power cord Prevent any exposed skin contact with heated seat too long to prevent low temperature burning In case the power cord is...

Page 5: ...Breakers Yes Yes Yes Located inside the seat function Yes Microwave sensing Manual flush Yes IoT function Refer to product configuration table Level III Refer to product configuration table Min water...

Page 6: ...ns All information in this instruction is based on the latest published product information We always persist in improving the quality of all Kohler products We reserve the right to change product fea...

Page 7: ...wash When seated press this button to enter rear wash auto stop after 5min or press STOP button to turn off immediately B C D E F G H I J K L Q Q A M N O P F Flush full Press this button to perform la...

Page 8: ...the remote control is almost used up Attach the remote control to the docking station and allow it to charge Note pairing operation can only be done under unseated status Cover and seat is powered on...

Page 9: ...ting indication function activated 2 Night light slow flush once long beep prolonged seating indication function deactivated D Rear wash Deodorizer function setting Remote setup instruction B C D E F...

Page 10: ...lkaline battery Do not place remote at a place where it may be splashed by liquid or immersed in liquid Do not place remote near hand dryer hair dryer etc small size home appliances to avoid disturban...

Page 11: ...Front wash Seat temp mid Night light ON Energy saving OFF Auto cover OPEN CLOSE ON Auto flush function ON Auto UV function ON Auto sterilization function ON Standby mode OFF Prolonged seating indicat...

Page 12: ...er When users intend to open or close the cover under normal condition the cover can open or close automatically against the trend of motion Users will not have to use force Once being stopped by any...

Page 13: ...hen users intend to open or close the seat under normal condition the seat can open or close automatically against the trend of motion Users will not have to use force Once being stopped by any obstac...

Page 14: ...ush function when power is off C Emergency flush 1 12 11 10 2 3 4 5 9 8 7 6 b For male use When cover is OPEN and toilet is in use Toilet will auto flush after unseated for a certain time Auto close s...

Page 15: ...1 Each function performance shall conform to factory setting 2 When use the front wash rear wash mode activate corresponding function auto deactivate after 5min D Press button to stop all functions B...

Page 16: ...n when detecting customer seated 2 Refer to Remote Setting for how to switch over auto deodorization function When filter almost expires orange LED keeps ON as shown When filter has expired and requir...

Page 17: ...the following rules during maintenance of your Kohler product Important Do not flush the cover directly by water including remote controller Maintenance In case of using a mixture of washing agent an...

Page 18: ...m ii In case of changing filter when power is off please pull filter out and plug in once to dismiss alarm after B Purification water filter exchange 1 Dismantle toilet cover Open toilet back cover an...

Page 19: ...ash or rear wash key on the side panel to extend the nozzle Use a wet soft brush to clean the nozzle Press one of the above keys or the stop key on remote control one more time The nozzle will retract...

Page 20: ...out Disconnect the power supply turn off stop valve with power cord Turn auto protection switch handle on without power cord Take out filter and clean it Cleaning the toilet filter Filter 1 Filter 2 W...

Page 21: ...o deodorizer block cavity to prevent fan or other parts damage F Water box drop When the machine is working there may be a little water flowing into the water box Please check and drop the box of wate...

Page 22: ...re and there is a risk of freezing in water pipe please turn off the tee valve and perform one flush or discharge the toilet 4 When use after long term idle status please close the tee valve and then...

Page 23: ...supply is closed C Power failure D Product is at standby mode E Wash mode is in progress F Auto flushing is deactivated Wash mode is abnormal A Wait until the water supply is restored B Fully open th...

Page 24: ...e seat temp set too low B Toilet is on standby mode A Please sit or leave the sensing area B Review Guide on remote controller setting C Wait until the flushing process is completed A Please close the...

Page 25: ...series contains this substance Note the information provided is based on the supplier data and Kohler inspection results The product is designed not to hurt the environment Under current technology al...

Page 26: ...27 29 30 30 31 33 35 36 37 39 39 39 40 40 40 40 40 41 41 47 48 1413624 T01 B 26 Kohler Co...

Page 27: ...III Kohler Co 27 1413624 T01 B...

Page 28: ...1413624 T01 B 28 Kohler Co...

Page 29: ...700mm x 418mm x 523mm 46kg 1 35 1 40 0 2MPa 500mL min 31 39 300s 5 33 UV IoT 3 0L 3 8L 2 6L 3 305 400mm 0 07MPa 0 74MPa 220V 50Hz 1080W 1600W 0 2MPa 15 Kohler Co 29 1413624 T01 B...

Page 30: ...UV 39 2 90 GB21551 2 2010 1413624 T01 B 30 Kohler Co...

Page 31: ...D 5 E C 5 B A A B C D E F G H I J K L Q M P Q A O N J 4 K F G H I Kohler Co 31 1413624 T01 B...

Page 32: ...M Q Q N O Q Q M N O P Q L Q Q Q Q P Q Q 1413624 T01 B 32 Kohler Co...

Page 33: ...G H 0 1 2 F D F G H J L N D B C D E F G H I J K L Q M P Q N O P 1 2 L UV N J E F G H J L N Kohler Co 33 1413624 T01 B...

Page 34: ...1 2 3 1413624 T01 B 34 Kohler Co...

Page 35: ...UV Kohler Co 35 1413624 T01 B...

Page 36: ...B A 1 2 3 33 40cm 33 4 1413624 T01 B 36 Kohler Co...

Page 37: ...1 12 11 10 2 3 4 5 9 8 7 6 A a Kohler Co 37 1413624 T01 B...

Page 38: ...b 1 2 33 B C 1 12 11 10 2 3 4 5 9 8 7 6 1 2 1413624 T01 B 38 Kohler Co...

Page 39: ...1 2 2 1 2 5 D B 2 C D 39 A E F UV Kohler Co 39 1413624 T01 B IoT IoT...

Page 40: ...UV 96 24ppm GB T 23131 1 2 1 2 33 3 1 2 1 2 3 4 42 UV UV 24 33 UV 1 2 UV UV UV 99 UV 18mm 8mm GB T 23131 UV UV 1413624 T01 B 40 Kohler Co...

Page 41: ...A Kohler Co 41 1413624 T01 B...

Page 42: ...4 5 B 1 2 3 i ii iii 1413624 T01 B 42 Kohler Co...

Page 43: ...2 C 2 2 Kohler Co 43 1413624 T01 B...

Page 44: ...D 1 3 2 1413624 T01 B 44 Kohler Co...

Page 45: ...E F Kohler Co 45 1413624 T01 B 22761T NA...

Page 46: ...5 4 b G a 1413624 T01 B 46 Kohler Co...

Page 47: ...E E 42 14 A B C D E A B C D E 15 A B A B Kohler Co 47 1413624 T01 B...

Page 48: ...GB T 26572 10 GB T 26572 10 Pb Hg PCBA PBB PBDE Cd Cr VI 1413624 T01 B 48 Kohler Co...

Reviews: