Kohler COUTURE ECO-LITE Installation Instructions Manual Download Page 6

6

114107-2-

CA

 (B)

Kohler Co., Kohler, WI

Hold the float under water for a few seconds to fill with
water for ballast.  Adjust the float by sliding it up or down
on the float rod until the water level is at the marked water
line on the flush valve overflow.

Check all connections for leaks for several days.

Float

Float Rod

Fig. #11

FLUSH CHAIN ADJUSTMENT

When the cam is in the 1.1 gallon flush position, there
should be a small amount of slack in the 1.6 gallon flush
chain.

When the cam is in the 1.6 gallon flush position, there
should be a small amount of slack in the 1.1 gallon flush
chain.

Study the illustrations carefully.

Make any adjustment to the flush chain lengths as
needed. Alternately test flush the toilet in the 1.1 gallon
and 1.6 gallon modes after each chain length adjustment.

When you are sure the toilet flushes properly in both flush
modes, count the number of extra chain beads at the top
of the trip arms. There should be no more than four extra
beads at the top of each trip arm. Cut off any excess.

1.6 Gallon Flush Position

Fig. #12

1.1 Gallon Flush Position

Water
Levels

Water
Levels

Note Cam
Position

Slack In 1.1 Gal.
Flush Chain

Note Cam
Position

Slack In 1.6 Gal.
Flush Chain

Summary of Contents for COUTURE ECO-LITE

Page 1: ...at the new toilet has the correct roughing in dimension The K 3471 K and K 3472 K have a 12 roughing in dimension See Fig 1 Be very careful while working with vitreous china products Vitreous china can break and chip if you overtighten bolts and nuts or carelessly handle the product Carefully inspect the new fixture for any sign of damage Observe all local plumbing and building codes Shut off the ...

Page 2: ...olts 2 5 16 diameter Toilet supply shut off valve 3 8 recommended If the existing toilet does not have a shut off valve below the tank install a shut off valve before installing the new toilet See Page 3 ROUGHING IN Fig 1 9 116 32 7 8 12 7 8 15 18 5 8 4 1 2 4 1 4 C OF OUTLET L 9 C B FRONT OF BOWL 3 8 I P S SUPPLY D A Roughing In Notes A B C D K 3471 K KU 29 1 2 15 5 8 6 1 8 9 1 2 K 3472 K KU 27 1 ...

Page 3: ...d discard NOTICE If a new toilet is not installed immediately temporarily stuff a rag in the closet flange Fig 2 Closet Flange Install new 5 16 diameter T bolts Fig 3 T Bolts Closet Flange TO INSTALL NEW SUPPLY SHUT OFF VALVE Install a toilet supply shut off valve so it is 9 above floorline and 4 1 2 to the left of the centerline of the closet flange The centerline of the supply shut off outlet sh...

Page 4: ...s washers and nuts onto the exposed T bolts Handtighten the nuts then tighten them an additional 1 2 turn with a wrench CAUTION Risk of product damage Overtightening may cause breakage or chipping If the T bolts extend more than 1 4 from the top of the nut cut off the excess Wipe away any residue Install the bolt caps Fig 6 Nut Washer Bolt Cap Base Bolt Cap TO INSTALL NEW TANK Make sure the three ...

Page 5: ...ff Valve Turn the shut off valve On and check for leaks If the connections are squarely assembled a slight retightening of the nuts will stop any leaks If the toilet is leaking between the tank and bowl carefully retighten the three tank bolts evenly Check all bowl and tank connections for leaks for several days OPERATION NOTES The long handle actuates the 1 6 gallon flush for typical solid waste ...

Page 6: ...allon flush position there should be a small amount of slack in the 1 1 gallon flush chain Study the illustrations carefully Make any adjustment to the flush chain lengths as needed Alternately test flush the toilet in the 1 1 gallon and 1 6 gallon modes after each chain length adjustment When you are sure the toilet flushes properly in both flush modes count the number of extra chain beads at the...

Page 7: ...inlet or supply line A Perform Corrective Action 2 A 5 Poor flush A Use of 1 1 gallon flush trip handle for solid waste removal B Trapway or rim holes are obstructed C Soil pipe or vent is obstructed D Low water level in bowl due to refill tube being plugged or out of overflow tube E Supply shut off valve not fully open A Actuate 1 6 gallon handle for maximum flushing performance 1 6 gallons B Unc...

Page 8: ...contractor or Kohler Co distributor please write us directly at Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your claim including a complete description of the product model numbers colors finishes and the date the product was installed Include a description of the problem and a photocopy of your invoice for ...