TO INSTALL NEW TOILET

Position the new toilet upside down on some padding.
Firmly place the gasket on the toilet outlet.

NOTE: If using a gasket with an integral plastic sleeve,
make sure the gasket is positioned facing away from the
toilet.

Remove the rag from the closet flange before setting the
toilet.

Carefully align and lower the toilet over the closet flange
and bolts.

CAUTION: Risk of concealed leakage. Do not lift
or rock toilet after placement; a new gasket must be
reapplied if you break the watertight seal.

Apply full body weight to the toilet rim to set the seal.

Fig. #5

Toilet Outlet

Gasket

Assemble the bolt cap bases, washers, and nuts onto the
exposed T-bolts. Handtighten the nuts, then tighten them
an additional 1/2-turn with a wrench.

CAUTION: Risk of product damage.
Overtightening may cause breakage or chipping.

If the T-bolts extend more than 1/4” from the top of the nut,
cut off the excess. Wipe away any residue. Install the bolt
caps.

Fig. #6

Nut

Washer

Bolt Cap Base

Bolt Cap

TO INSTALL NEW TANK

Make sure the three tank bolts extend fully through the
holes in the gasket. Set the tank onto the bowl using the
bolts as a guide. Center the gasket on the inlet of the bowl.
Assemble the washers and brass hex nuts onto the bolts.

CAUTION: Risk of product damage.
Overtightening may cause breakage or chipping.

Alternately tighten the three brass hex nuts so that the top
of the tank is level with the top of the bowl, and a watertight
seal is obtained.

Fig. #7

Tank Bolt

Gasket

Washer

Nut

Summary of Contents for COUTURE ECO-LITE

Page 1: ...at the new toilet has the correct roughing in dimension The K 3471 K and K 3472 K have a 12 roughing in dimension See Fig 1 Be very careful while working with vitreous china products Vitreous china can break and chip if you overtighten bolts and nuts or carelessly handle the product Carefully inspect the new fixture for any sign of damage Observe all local plumbing and building codes Shut off the ...

Page 2: ...olts 2 5 16 diameter Toilet supply shut off valve 3 8 recommended If the existing toilet does not have a shut off valve below the tank install a shut off valve before installing the new toilet See Page 3 ROUGHING IN Fig 1 9 116 32 7 8 12 7 8 15 18 5 8 4 1 2 4 1 4 C OF OUTLET L 9 C B FRONT OF BOWL 3 8 I P S SUPPLY D A Roughing In Notes A B C D K 3471 K KU 29 1 2 15 5 8 6 1 8 9 1 2 K 3472 K KU 27 1 ...

Page 3: ...d discard NOTICE If a new toilet is not installed immediately temporarily stuff a rag in the closet flange Fig 2 Closet Flange Install new 5 16 diameter T bolts Fig 3 T Bolts Closet Flange TO INSTALL NEW SUPPLY SHUT OFF VALVE Install a toilet supply shut off valve so it is 9 above floorline and 4 1 2 to the left of the centerline of the closet flange The centerline of the supply shut off outlet sh...

Page 4: ...s washers and nuts onto the exposed T bolts Handtighten the nuts then tighten them an additional 1 2 turn with a wrench CAUTION Risk of product damage Overtightening may cause breakage or chipping If the T bolts extend more than 1 4 from the top of the nut cut off the excess Wipe away any residue Install the bolt caps Fig 6 Nut Washer Bolt Cap Base Bolt Cap TO INSTALL NEW TANK Make sure the three ...

Page 5: ...ff Valve Turn the shut off valve On and check for leaks If the connections are squarely assembled a slight retightening of the nuts will stop any leaks If the toilet is leaking between the tank and bowl carefully retighten the three tank bolts evenly Check all bowl and tank connections for leaks for several days OPERATION NOTES The long handle actuates the 1 6 gallon flush for typical solid waste ...

Page 6: ...allon flush position there should be a small amount of slack in the 1 1 gallon flush chain Study the illustrations carefully Make any adjustment to the flush chain lengths as needed Alternately test flush the toilet in the 1 1 gallon and 1 6 gallon modes after each chain length adjustment When you are sure the toilet flushes properly in both flush modes count the number of extra chain beads at the...

Page 7: ...inlet or supply line A Perform Corrective Action 2 A 5 Poor flush A Use of 1 1 gallon flush trip handle for solid waste removal B Trapway or rim holes are obstructed C Soil pipe or vent is obstructed D Low water level in bowl due to refill tube being plugged or out of overflow tube E Supply shut off valve not fully open A Actuate 1 6 gallon handle for maximum flushing performance 1 6 gallons B Unc...

Page 8: ...contractor or Kohler Co distributor please write us directly at Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your claim including a complete description of the product model numbers colors finishes and the date the product was installed Include a description of the problem and a photocopy of your invoice for ...