5A.9
Section 5A
LPG Fuel Systems
5A
Vaporizer Assembly
The outer surface of the vaporizer should be kept free
of dirt and debris accumulation, which will cause a
loss of vaporization efficiency. Visual inspection and
necessary cleaning should be performed on a regular
basis, more frequently under dusty or dirty
conditions. The vaporizer should be disassembled,
cleaned, and serviced using a rebuild kit
every 1500
hours
or if a problem is encountered.
Figure 5A-17.
LPG Regulator
The regulator controls both the pressure and flow of
fuel within the LP system. It is comprised of both a
primary and secondary chamber, which are dependent
upon one another. Two different styles of regulators
are used, based upon the system involved. The Impco
(Beam) regulator is shown in Figure 5A-18, and the
Nikki regulator is shown in Figure 5A-19. Although
the basic design and operating principles are similar,
due to system differences the regulators should not be
interchanged.
Figure 5A-18. Impco (Beam) Regulator.
Figure 5A-19. Nikki Regulator.
Following are separate sections covering the theory of
operation and general service information for each
style of regulator. Detailed service/repair instructions
are included in the rebuild kit for each regulator.
Summary of Contents for COMMAND CH18-CH26
Page 1: ...6 59 0 18 25 217 5 1 6 7 200 1 ...
Page 2: ......
Page 4: ......
Page 30: ...3 6 Section 3 Troubleshooting ...
Page 101: ......
Page 102: ......
Page 105: ......
Page 124: ... 6HFWLRQ XEULFDWLRQ 6 VWHP ...
Page 130: ...7 6 Section 7 Retractable Starter ...
Page 176: ... 6HFWLRQ OHFWULFDO 6 VWHP DQG RPSRQHQWV ...
Page 196: ...9 20 Section 9 Disassembly ...
Page 242: ... 6HFWLRQ 5HDVVHPEO ...
Page 245: ......