background image

-4-

7. The installation of pinch plate, the pinch plate installation

provides another method for faceplate, that is, the
faceplate don't rely on the position of the in wall tank and
the mask, and can directly install the faceplate to the false
wall. The location of faceplate to refer the 1 meter high
from the finished floor to center of faceplate is
recommended. 7~20mm thickness is recommended for the
wall of the pinch plate and at least 80mm gap is reserved.
Recommended the installation hole size of
201

X 136

mm. See figure

8. The installation of mask, 4 holes with diameter of 10mm

and depth of 16mm are needed to be reserved at the
locating hose. Drill 10mm holes through air hose on the
side of mask. See figure

7.

1

7~20mm

80mm

201

X 136

mm

8.

4

10mm

16mm

10mm

+2

0

+2

0

+2

0

+2

0

At least 80mm gap reserved

80mm

Air hose

Pinch plate

Finished wall

Supporting
Board

7~20mm recommended

7~20mm

201

136

+2

0

+2

0

Height

Suggested/

1150

4

Finished Floor

1098

4

1066

4

1048

4

267

5

100

3

35

2

52~230

478

3

438

3

230

3

180

3

667

4

1000

205

3

Air hose

Finished
wall

Fix Mask Onto Wall

10 Hole through hose
10

10 Depth 16,
Space reserved
10

16

72

1331845-T01-B

Summary of Contents for BEAM K-23056T

Page 1: ...in the tank Kohler will not be responsible for any damage related to above mentioned cleanser or solvent Do not apply spares that are not provided by Kohler and please note that glass adhesive tape shall not be applied to the installation of Kohler spares Kohler will not be responsible for any damage related to installation with spares not provided by Kohler Region SKU number SKU Rated voltage Rat...

Page 2: ...set 4pcs 4pcs 4pcs A Transformer Installation Warning Before the in wall tank is installed the transformer is installed on the wall first It is recommended to place transformers on the ceiling or other hidden and easy to operate places As illustrated the output connector of transformer with 2 core female connector through the bushing pipe the bushing pipe dia 16 20 is recommended into water tank C...

Page 3: ...sh Air Hose Input Signal Cable Input Signal Cable Rib A A Slot A A Slot B B Rib B B 5 Install air pump assembly needs attention the slot of faceplate and the rib of air pump needs install properly to correspond A A B B Prevent installation improperly See figure 6 Connect big flush air hose and half flush hose to outlet joint in air pump assembly Connect power output cable of transformer and power ...

Page 4: ...he installation hole size of 201 X 136 mm See figure 8 The installation of mask 4 holes with diameter of 10mm and depth of 16mm are needed to be reserved at the locating hose Drill 10mm holes through air hose on the side of mask See figure 7 1 7 20mm 80mm 201 X 136 mm 8 4 10mm 16mm 10mm 2 0 2 0 2 0 2 0 At least 80mm gap reserved 80mm Air hose Pinch plate Finished wall Supporting Board 7 20mm recom...

Reviews: