background image

   

                                                                               

1327567-2A-D                                   

                                                                                                                 2   

  

   

                                                                               

1327567-2A-D                           

                                                                                                                         3  

  

2

4
5

6

8

7

1

3

HANDLE OPERATION

Turn the upper handle clockwise for cold water; Turn the lower handle counter-clockwise for hot water.

Lift and turn the diverter for handshower. Turn the diverter in the normal position for bath spout.

INSTALLATION

How to Install the Faucet

Shut off water supply. Cut away the extending 

part of the base protector(1) in accordance with 

the tile surface. Remove the plug(2) from the 

base. Remove the protector(3) from the faucet. 

Slide up the escutcheon kit(4). Install the faucet. 

NOTE: 

Keep the faucet vertical to the base, to 

avoid damaging the O-rings on the bottom. 

Keep the “KOHLER” logo on the body pointing 

to tub. Fix the faucet to the base with the 

screws(5) and washers(6) through the flange(7). 

Tighten the screws with hex wrench(8).

Slide down the escutcheon kit, make sure it is 

against the finished floor.

How to Install the Spout

Remove the protector(10) from the spout(9). 

Install the spout into the body. Position the 

spout. Make sure it is vertical to the handles. 

Tighten the screws(11). Insert the plugs(12). 

How to Install the Handshower

If needed, install the regulator(13) into the inlet 

of the handshower(14). Remove the protector 

(10) from the connector(15) of the diverter kit. 

Connect the hose(16) to the diverter kit and 

handshower with washers. Tighten all the 

connections. 

Hang the handshower on the bracket(17). 

INSTALLATION CHECKOUT

Ensure that all coupling nuts are tight. 

Ensure that the handle is in the off position. 

Turn on the main water supply, and check for 

leaks. Repair as needed.

Remove the aerator(19) by key(18). Remove 

the handshower(14). Turn on faucet handle. 

Run hot and cold water through spout for 

about one minute to remove any debris. 

Check for leaks at this time. Remove any 

debris. Shut off the faucet. Reinstall the 

aerator and handshower.

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft 

cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc

which could adversely 

affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

CLEANING INSTRUCTIONS

Katalyst Air

Intense Massage

How to Operate the Handshower

Press the buttons of the handshower to 

change water flow. 

How to Maintain the Handshower

Any debris or mineral build-up may cause the 

flow stream to become distorted or reduce the 

flow rate. To remove the debris or mineral 

build-up, run water through the handshower, 

firmly press or rub your finger back and forth 

across the rubber nozzles.

Remove and clean the screen washer.

14

17

15

13

9

10

11

11

12

12

16

14

19
18

Reviews: