background image

   

                                                                               

1124477-2A-G                                  

                                                                                                                  

  

  

INSTALLATION

How to Install the Faucet

To perform installation, installer must provide G1/2

˝ 

female supply 

fittings(1), spaced 150mm apart and level. The supply fittings should 

be vertical and not beyond the finished wall. Hot supply pipe must be 

located on the left.

Flush the water supply pipes thoroughly to remove debris.

Install the two offset connectors(2) into the hot and cold supply pipes. 

Use appropriate thread sealants or thread tape on pipe threads.

Adjust the center-to-center distance between the connectors to 

150mm and level. Thread the escutcheons(3) onto the connectors 

until they are against the finished wall. 

Put the washers(4) into the nuts(5), thread the nuts to connectors. 

Tighten the nuts with strap wrench or soft cloth between product and 

regular wrench.

1

150mm

3

Hot

Cold

   

                                                                               

1124477-2A-G                                  

                                                                                                                  

  

  

How to Install the Shower Bracket

Determine a suitable location on the finished wall to install the 

bracket. Mark bracket base mounting hole locations on the wall 

according to the dimension. Drill two holes on the finished wall, the 

holes should match the anchors(31). Install the anchors. 

Tighten screws(32) to secure bracket base(33, flat side upward). 

Put the bracket(30) onto the bracket base and lock by stopper.

How to Install the Handspray and the Hose

Tighten 500mm length hose(20) to the outlet(21) and the 

connector(22) with two washers(19).

Lift the faucet diverter. Turn the diverter handle(23) to the vertical 

upwards and run hot and cold water for one minute to remove any 

debris.

Tighten the end A of 1500mm length hose(26) to the connector(25) 

with filter washer(24). Tighten the end B of the hose(26) to the 

handspray(27) with filter washer(24). 

24

19

21

27

27

24

How to Install the Showerhead

Lift the faucet diverter, turn the diverter handle(23) to the vertical 

downwards and run hot and cold water for one minute to remove any 

debris before the showerhead (28) is installed. Connect the 

showerhead to the tube kit outlet with the washer(29), and tighten the 

showerhead with strap wrench. 

2

5

4

28

29

How to Install the Slide Bar

Select a location in vertical wall to install shower column according to 

rough-in dimensions.

Drill the lower hole to install a anchor as anchors(6) diameter in the 

vertical position in the finished wall. Press a anchor into the hole. 

Secure the base(9) by the self-tapping screw(7) with the washer(8). 

Rehearse the slide bar kit(10) installation for the upper anchor 

mounting location determination. Slide the base(11) onto the 

connector(12) that insert into the base about 26mm. Screw the 

screws(14) into the base(11) with the hex wrench(13), and tighten 

them.

Install the diverter body(15) onto the base(9). Place the diverter body 

and the base(11) against the finished wall. Mark the diameter

of the base(11) with a pencil. Remove the slide bar kit. Loosen the 

screws(14) with the hex wrench (

NOTE:

 Don’t lose the screws.), 

remove the base(11). Mark the center point of the base diameter with 

a pencil. 

Drill a hole on the center point as anchors(6) diameter. Press a 

anchor into the hole. Secure the base(11) by the self-tapping screw(7) 

with the washer(8), and make sure two screw holes of the base(11) 

vertically downwards. 

Remove and discard the guard from the tube kit(16), then install it into the slide bar kit. Install the nut(17) onto 

the tube kit with soft cloth between internal hole of the nut and the tube kit. Then screw the nut onto the slide 

bar kit with strap wrench or soft cloth between the nut and regular wrench.

Install the connector(12) and the diverter body(15) to the base, and place the diverter body against the 

finished wall, and the connector insert into the base(11) about 26mm.

Screw the screw(18) into the diverter body with the hex wrench, and tighten it. Tighten the screws(14) with 

the hex wrench.

13

7

6

7

8

8

11

9

16

10

17

12

15

14

18

Ø30mm

6

Center Point

Base Diameter

27

32

30

33

31

A

B

23

26

24

25

20

22

19

Reviews: