How to Install the Faucet
To perform installation, installer must provide G1/2
˝
female supply
fittings(1), spaced 150mm apart and level. The supply fittings should
be vertical and not beyond the finished wall. Hot supply pipe must be
located on the left.
Flush the water supply pipes thoroughly to remove debris.
Install the two offset connectors(2) into the hot and cold supply pipes.
Use appropriate thread sealants or thread tape on pipe threads.
Adjust the center-to-center distance between the connectors to
150mm and level. Thread the escutcheons(3) onto the connectors
until they are against the finished wall.
Put the washers(4) into the nuts(5), thread the nuts to connectors.
Tighten the nuts with strap wrench or soft cloth between product and
regular wrench.
1
150mm
3
Hot
Cold
1124477-2A-G
3
How to Install the Shower Bracket
Determine a suitable location on the finished wall to install the
bracket. Mark bracket base mounting hole locations on the wall
according to the dimension. Drill two holes on the finished wall, the
holes should match the anchors(31). Install the anchors.
Tighten screws(32) to secure bracket base(33, flat side upward).
Put the bracket(30) onto the bracket base and lock by stopper.
How to Install the Handspray and the Hose
Tighten 500mm length hose(20) to the outlet(21) and the
connector(22) with two washers(19).
Lift the faucet diverter. Turn the diverter handle(23) to the vertical
upwards and run hot and cold water for one minute to remove any
debris.
Tighten the end A of 1500mm length hose(26) to the connector(25)
with filter washer(24). Tighten the end B of the hose(26) to the
handspray(27) with filter washer(24).
24
19
21
27
27
24
How to Install the Showerhead
Lift the faucet diverter, turn the diverter handle(23) to the vertical
downwards and run hot and cold water for one minute to remove any
debris before the showerhead (28) is installed. Connect the
showerhead to the tube kit outlet with the washer(29), and tighten the
showerhead with strap wrench.
2
5
4
28
29
How to Install the Slide Bar
Select a location in vertical wall to install shower column according to
rough-in dimensions.
Drill the lower hole to install a anchor as anchors(6) diameter in the
vertical position in the finished wall. Press a anchor into the hole.
Secure the base(9) by the self-tapping screw(7) with the washer(8).
Rehearse the slide bar kit(10) installation for the upper anchor
mounting location determination. Slide the base(11) onto the
connector(12) that insert into the base about 26mm. Screw the
screws(14) into the base(11) with the hex wrench(13), and tighten
them.
Install the diverter body(15) onto the base(9). Place the diverter body
and the base(11) against the finished wall. Mark the diameter
of the base(11) with a pencil. Remove the slide bar kit. Loosen the
screws(14) with the hex wrench (
NOTE:
Don’t lose the screws.),
remove the base(11). Mark the center point of the base diameter with
a pencil.
Drill a hole on the center point as anchors(6) diameter. Press a
anchor into the hole. Secure the base(11) by the self-tapping screw(7)
with the washer(8), and make sure two screw holes of the base(11)
vertically downwards.
Remove and discard the guard from the tube kit(16), then install it into the slide bar kit. Install the nut(17) onto
the tube kit with soft cloth between internal hole of the nut and the tube kit. Then screw the nut onto the slide
bar kit with strap wrench or soft cloth between the nut and regular wrench.
Install the connector(12) and the diverter body(15) to the base, and place the diverter body against the
finished wall, and the connector insert into the base(11) about 26mm.
Screw the screw(18) into the diverter body with the hex wrench, and tighten it. Tighten the screws(14) with
the hex wrench.
13
7
6
7
8
8
11
9
16
10
17
12
15
14
18
Ø30mm
6
Center Point
Base Diameter
27
32
30
33
31
A
B
23
26
24
25
20
22
19