background image

BEFORE YOU BEGIN

12959-4    72704-4   Wall-Mount Bath & Dual Shower Faucet

ROUGH-IN DIMENSIONS

Wall-Mount Bath & Dual Shower Faucet

G1/2˝

G1/2˝

G1/2˝

G1/2˝

1500

500

150

Ø67

G1/2˝

   

                                                                               

1124477-2A-G                                 

                                                                                                                   

  

  

G1/2˝

155

30º

   

                                                                       

1124477-2A-G                             

                                                                                                                       

1   

  

All information is based on the latest product information available at the time of publication. Kohler Co. 

reserves the right to make changes in product characteristics, packaging, or availability at any time without 

notice. 

Please leave these instructions for the consumer. They contain important information.

NOTES:

1. Shut off the water supplies to the fitting.

2. Inspect the supply tubing for damage. Replace as necessary.

3. Observe local plumbing codes.

4. The minimum inlet water pressure for diverter is 0.05MPa(0.5bar).

5. Recommended minimum working pressures is 1bar(0.1Mpa).

6. The highest working pressure for showerhead & handspray is 0.5MPa(5bar). If it exceeds 0.5MPa(5bar), a 

pressure reducer is needed. The highest water and environment temperature is 60°C. Please keep 

handspray showerhead and the shower arm away from heater, or it may become damaged and cause injury 

to the user.

Ensure that all connections are tight. Ensure that the handle is in the 

off position.

Turn on the drain and main water supply, and check for leaks. Repair 

as needed.

Remove the aerator assembly(34). Run hot and cold water through 

spout about one minute to remove any debris. Clean the aerator 

assembly. Shut off the faucet. Reinstall the aerator assembly.

INSTALLATION CHECKOUT

34

CLEANING INSTRUCTIONS

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean 

soft cloth. Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could 

adversely affect the finish and are not recommended for cleaning.

Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

66

19

Four-way Handspray

(Only for 12959-4)      

Only for 72704-4    

61

Ø145

400

809

1098~1298

1108~1308

62

875~1075

G1/2˝

G1/2˝

Recommended Height

1000~1100

    

  

34

Finished Floor

OPERATION INSTRUCTIONS

Lift the handle slightly to turn on the faucet. Turn to vertical position for cold water, horizontal position for hot 

water. Water flows out from spout when faucet diverter is in the normal position and it’s diverted to shower 

column when the diverter knob is lifted.  

Turn the diverter handle to the vertical upwards, water will flow from the handspray; turn it to the vertical 

downwards, the showerhead will work; turn it to the position between the vertical upwards and the vertical 

downwards, water will flow the showerhead and the handspray. 

 

INSTALLATION INSTRUCTIONS 

Ø102

234

G1/2˝

  71

49

40º

27

60

58

Reviews: