Kohler 5EFKOD Installation Instructions Manual Download Page 8

8

TT-1583 9/13

1.15.5 USB Flowchart

USB:

SAVE

PARAMS & LOG

USB:

LOAD

PARAMS

USB:

LOAD

SOFTWARE

CONFIRM

SAVE:

NO

Rotate Knob

Rotate Knob

Push

Knob

Rotate Knob

USB Stick
Present

CONFIRM

SAVE:

YES

Rotate

Knob

Saving...

Push

Knob

Save

complete

Filename

PUSH TO LOAD

Push

Knob

Loading...

Push

Knob

Load

Complete

Filename

PUSH TO LOAD

Push

Knob

Loading...

Push

Knob

Load

Complete

Skipped if Genset is Running

Note: Ignored until generator set stops running.

Note:

Before inserting a mass-storage device (USB

host connector), power off and then power on the

controller.

See Figure 5 for tested/approved manufacturer’s USB
flash drive types that work with the ADC IId controller.

CustomUSB

(Kohler

Power Systems

Part Number KW-A202)

2-GB “spin” full size

Imation

4-GB full size

Lexar

4-GB full size

PNY

4-GB full size and micro

Verbatim

4-GB full size and micro

Figure 5

USB Types Tested/Approved for ADC IId

Summary of Contents for 5EFKOD

Page 1: ...st set the controller parameters On the ADC IId controller the installer can use the key sequence described in these instructions Use the pushbutton rotary selector dial to navigate to the respective...

Page 2: ...rforming voltage tests 1 Remove all jewelry 2 Stand on a dry approved electrically insulated mat 3 Do not touch the enclosure or components inside the enclosure 4 Be prepared for the system to operate...

Page 3: ...item Overview Turn the rotary dial to select the desired fixed view Overview Auto Scrolling Display Overview hr Avg V L L V Active Shutdowns if present Eng Runtime h Frequency Hz Oil Pressure PSI Bat...

Page 4: ...sh and hold the pushbutton rotary selector dial until the Calibration Enabled popup appears Calibration of each display is now available The display will show the following values for three phase gene...

Page 5: ...isplay for Measurement System is user selectable as English or Metric Contrast display is user adjustable to help improve digital display visibility in dimly lit rooms or in direct sunlight Note The c...

Page 6: ...w available The user can change the individual value or can select Reset VR Yes to reset to the default value The Reset VR Settings display will only show if editing is enabled To disable calibration...

Page 7: ...manual for voltage reconnection information With the generator set stopped go to the Volt Select menu Then push and hold the pushbutton rotary selector dial until the voltage selection starts to flas...

Page 8: ...sh Knob Load Complete Skipped if Genset is Running Note Ignored until generator set stops running Note Before inserting a mass storage device USB host connector power off and then power on the control...

Page 9: ...9 TT 1583 9 13 GM79008 C Figure 6 Wiring Diagram Point to Point...

Page 10: ...10 TT 1583 9 13 Notes...

Page 11: ...11 TT 1583 9 13 Notes...

Page 12: ...stems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone 65 6264 6422 Fax 65 6264 6455 Availability is subject to change without notice Kohler Co reserves the right to change the desi...