TP-6391 9/08
42
Section 4 Controller
Marine Gasoline
Freq
Volts,
Hz
Market
Engine
Type
Data
Inputs
CO
Battery
Voltage
CANbus
Comm.
Marine Gasoline
Model
Freq.
Hz
Voltage, Phases
Uu*
Uc
Ec
Ed
[
CO
Bt
Cn
]
230 V, 1 Ph, 2 W
2
4EFCD
50
115/230 V, 1 Ph, 3 W
6
4EFCD
50
115 V, 1 Ph, 2 W
5
120/240 V, 1 Ph, 3 W
1
5ECD
60
120 V, 1 Ph, 3 W
0
ECD
5ECD
60
120 V, 1 Ph, 2 W
0
0
4
0
1
12
2 or 8
]
ECD
EFCD
230 V, 1 Ph, 2 W
2
0
4
0
1
12
2 or 8
]
6EFCD
50
115/230 V, 1 Ph, 3 W
6
6EFCD
50
115 V, 1 Ph, 2 W
5
120/240 V, 1 Ph, 3 W
1
7.3ECD
60
120 V, 1 Ph, 3 W
0
7.3ECD
60
120 V, 1 Ph, 2 W
0
* Use voltage/frequency parameters Uu07--Uu23 only with ADC application program version 1.20 or higher.
[
See Figure 4-19 for Ed settings with optional sender kits.
]
See Figure 4-20 for Cn settings with optional digital gauges (gauges are available on selected models only).
Note:
Replacement controllers from Kohler Aftermarket Parts are shipped with factory settings for the 8.5/12RES.
Note:
Setting the Ec parameter automatically selects the Ed parameter for the standard data inputs for that engine.
If you change Ec, check the Ed setting.
Figure 4-18
Configuration Parameters
Model
Sender Kit
Ed
5/7.3ECD
None
0
5/7.3ECD
4/6EFCD
GM45891-KA1 *
No Change
* OP and WT sender kits
Figure 4-19
Ed Settings with Optional Sender Kits
Gauge Kit
Gauge Description
Cn
Setting
Power Down
Time (when
master switch in
AUTO position)
Description
None
—
Cn00
48 hours
No CAN communication (not for use with these models)
GM32337-KP1 Remote Digital Gauge for
Marine
Cn01
Never/None
3-inch J1939 gauge with no sleep mode
CAN communication (not for use with these models)
GM46035-KP1 Three-Inch Digital Gauge
Cn02
48 hours
Smartcraft
t
3-inch gauge for generator set #1 with ECM
[
g
g
Cn03
48 hours
Smartcraft
t
3-inch gauge for generator set #2 with ECM
[
Cn04
48 hours
Smartcraft
t
3-inch gauge for generator set #3 with ECM
[
Cn05
48 hours
Smartcraft
t
3-inch gauge for generator set #4 with ECM
[
Cn07
48 hours
Smartcraft
t
3-inch gauge for generator set #1 without ECM
[
(not for use with these models)
GM50822-KP1 Two-Inch Digital Gauge
Cn08
1 hour
w
Smartcraft
t
2-inch gauge for generator set #1 with ECM
]
g
g
Cn09
1 hour
w
Smartcraft
t
2-inch gauge for generator set #1 without ECM
]
(not for use with these models)
* For ADCs with removable power mode jumpers, refer to TT-1439 for power down information.
[
Smartcraft
t
settings for ADC code version 2.00 or higher only, for models 5/7.3ECD and 4/6EFCD.
]
Smartcraft
t
settings for ADC code version 2.20 or higher only.
w
Before ADC code version 3.20, the power-down time was 48 hours.
SmartCraft
t
is a trademark of Mercury Marine, a division of Brunswick Corporation.
Figure 4-20
Communication Parameter Cn Settings (optional gauges are available on selected models only)