TT-1715

2/17

13

Digital

Gauge

Display

ADC IId

Display

SiteTech

Display

Description

No faults

47

ERR

Oil Pres Low Shutdwn

Low Engine Oil Pressure

Shutdown: Low Oil Pressure

47

WARN

Oil Pres Low Warning

Low Engine Oil Pressure

Warning: Low Oil Pressure

53

WARN

Lo Crank Vlt Warning

Low Cranking Voltage

Warning: Weak Battery

62

ERR

Sea Pressur Low Shutdwn

Low Engine Seawater Pressure

Shutdown: Sea Pump Pressure

64

ERR

Engine Speed High Shutdwn

High Engine Speed

Shutdown: Engine Overspeed

65

ERR

Coolant Temp High Shutdwn

High Engine Coolant Temperature

Shutdown: Coolant Sensor Range High

65

WARN

Coolant Temp High Warning

High Engine Coolant Temperature

Warning: Coolant Sensor Range High

HB

WARN

Battery High Warning

High Battery Voltage

Warning: High Battery Voltage

LB

WARN

[

Battery Low Warning

Low Battery Voltage

Warning: Low Battery Voltage

OC

ERR

[

Over Crank Shutdwn

Locked Rotor Shutdwn

Over Crank

Locked Rotor

Shutdown: Over Crank or Locked Rotor

AF

ERR

[

Aux Input Shutdwn

Auxiliary Input

Shutdown: Auxiliary Fault Input

OU

ERR

Volts xx--xx High Shutdwn

High Generator Voltage xx--xx

Shutdown: Over Voltage

UU

ERR

Volts xx--xx Low Shutdwn

Low Generator Voltage xx--xx

Shutdown: Under Voltage

OF

ERR

Frequency High Shutdown

High Generator Frequency

Shutdown: Over Frequency

UF

ERR

[

Frequency Low Shutdown

Low Generator Frequency

Shutdown: Under Frequency

ERR *

Not available

Not available

Shutdown: Unknown/Not Supported Shutdown

WARN *

Not available

Not available

Warning: Unknown/Not Supported Warning

1000

ERR *

Not available

Not available

ECU Data Loss (generated by gauge)

1001

ERR *

Not available

Not available

Start Fault (generated by gauge)

1002

ERR *

Not available

Not available

Stop Fault (generated by gauge)

* Fault generated by the digital gauge.

[

Check the controller’s display to see more detailed information regarding the fault. See Section 16.

Figure 16

Fault Codes Displayed for ADC IId Faults

Summary of Contents for 4-8EFKD

Page 1: ...own The current software versions are located in TechTools on the Kohler Power Resource Center Access the TechTools site to update the controller software to the version indicated in Figure 3 Model Controller Software Version 5 10EKD 4 8EFKD ADC II 1 8 4 6EKOD 5EFKOD ADC IId 4 4 0 9 11EKOZD 7 9EFKOZD Figure 3 Controller Software Updates Safety Precautions Observethefollowingsafetyprecautionswhilei...

Page 2: ... may accumulate If operating the generator set dockside moor the craft so that the exhaust discharges on the lee side the side sheltered from the wind Always be aware of others making sure your exhaust is directed away from other boats and buildings Explosion Gasoline vapors can cause explosion and severe injury or death Before starting the generator set engine operate the blower 4 minutes and che...

Page 3: ...s GM96782 6 pin connector end to the 6 pin connector on the gauge See Figure 6 2 4 Connect the wiring harness GM96782 12 pin connector end to the generator set s customer interface 12 pin connector See Figure 6 and Figure 7 Use a remote extension harness if additional length is required Note Order a remote extension harness kit if required DO NOT use more than 3 remote harness kits and DO NOT exce...

Page 4: ...an ADC II Controller For Units with an ADC IId Controller Figure 6 Remote Two Inch Digital Gauge Diagram Shown on Non Sound Shielded Unit 1 Remote interface connector 1 1 Shown on Sound Shielded Unit Figure 7 Remote Customer Interface Connector Typical ...

Page 5: ...erator sets with an ADC IId controller Set the CAN A parameter under the Gen Set System menu to NMEA 2000 Consult the generator set operation manual for full instructions to set the CAN A parameter Configuration Mode The configuration mode can be selected from any other mode by pressing and holding the MODE button for 5 seconds While in the configuration mode use the MODE button to select the desi...

Page 6: ...the descriptions of displayed faults Gauge Operation 7 Pushbuttons Three pushbuttons control the gauge functions See Figure 11 D MODE button Used to change the function of the LCD display and access submenus and adjust settings D START arrow up button Y Used to move between screens start the generator and modify settings D STOP arrow down button B Used to move between screens stop the generator an...

Page 7: ...ockwise direction Ifthe generator isnotrunning all asterisk segments will remain on and will not blink D Start Stop Mode Allows remote starting and stopping of the generator set engine See Section 9 Generator Start Stop for operation sequence D Sleep Mode After one hour of generator set and gauge inactivity the backlight display turns off D Fault Mode Displays the fault and warning codes as shown ...

Page 8: ...eleased too fast the gauge will go back to the normal mode without sending the start command If the generator was successfully started the gauge will gointothenormalmodeand displaythe HRScharacters hours screen Blinking asterisk segments will appear next to these characters on the LCD screen to indicate the generator is running 11 Using the GEN STOP Function 11 1 Press the MODE button until GEN ST...

Page 9: ... to the normal mode However if the error remains the gauge remains in the fault mode After correcting the error the user must resend the clear fault message to the controller by pressing the mode button For more information see Section 16 Controller Fault Codes 15 GEN START Fault Codes The normal mode can function if a fault WARN code appears on the gauge however it will remain disabled if an ERR ...

Page 10: ...ing Spark 2 Timing Low 42 ERR Fault EST 2 Low Shutdown Spark 2 Timing Low 43 WARN EST 2 High Warning Spark 2 Timing High 43 ERR Fault EST 2 High Shutdown Spark 2 Timing High 46 ERR Fault Injector Shutdown Injector Fault 47 ERR Fault Low oil pres Shutdown Low Oil Pressure 47 WARN Low oil pres Warning Low Oil Pressure 48 ERR Fault ETC spring Shutdown ETC Engine Throttle Control Spring Test Failed 49...

Page 11: ...r Warning Oil Pressure input Low Hb WARN High battery Warning High Battery Voltage Lb WARN Low Battery or Weak battery Warning Low Battery Voltage OC ERR Fault Over crank or Fault Locked rotor Shutdown Over Crank LOC ERR Fault Coolant loss Shutdown Loss of Coolant AF ERR Fault Auxiliary Fault Hi exh temp Fault ECM voltage Fault HVR Comm Err Shutdown Auxiliary Fault Input Shutdown High Exhaust Gas ...

Page 12: ... Supported Warning ERR Not available Shutdown Unknown Not Supported Shutdown 1000 ERR Not available ECU Data Loss generated by gauge 1001 ERR Not available Start Fault generated by gauge 1002 ERR Not available Stop Fault generated by gauge Fault generated by the digital gauge Check the controller s display to see more detailed information regarding the fault See Section 16 Figure 15 Fault Codes Di...

Page 13: ...e OC ERR Over Crank Shutdwn Locked Rotor Shutdwn Over Crank Locked Rotor Shutdown Over Crank or Locked Rotor AF ERR Aux Input Shutdwn Auxiliary Input Shutdown Auxiliary Fault Input OU ERR Volts xx xx High Shutdwn High Generator Voltage xx xx Shutdown Over Voltage UU ERR Volts xx xx Low Shutdwn Low Generator Voltage xx xx Shutdown Under Voltage OF ERR Frequency High Shutdown High Generator Frequenc...

Page 14: ...14 TT 1715 2 17 Notes ...

Page 15: ...TT 1715 2 17 15 Notes ...

Page 16: ...er Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone 65 6264 6422 Fax 65 6264 6455 Availability is subject to change without notice Kohler Co reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever Contact your local Kohlerr generator set distributor for availability 2017 by Kohler Co All rights reserved ...

Reviews: