background image

5

08774-W2-A

Connect the shower fittings

1.  Install the shower fittings (refer to the manufacturer’s instructions).

2.  Connect the shower fittings to the mixer.

finish the Installation

.  Make sure that the mixer knobs are in the off position.

2.  Turn on the hot and cold water supplies and check for leaks from both the mixer 

and the drain.

3.  use the special key (provided) to unscrew and remove the aerator.

4.  Turn on the hot and cold knobs and allow the water to run for approximatley 

one minute to remove any debris.

5.  Turn the hot and cold knobs to the off position and re-install the aerator using 

the special key.

Operation

set the temperature by slowly turning the temperature selector (right handle).
for safety reasons there is a stop that limits the tempeature to 38°c. To get a higher 

temperature, push the button and contiue turning the temperature selector

Tool

Aerator

Shower

Summary of Contents for 10089W-CP

Page 1: ... retained with the product for maintenance and operational purposes Installation and User Guide Oblo Deck and Wall Mounted Bath Shower Mixers and Wall Mounted Thermostatic Shower MODEL NUMBERS Important Please quote the above model number s when ordering spares 10089W CP 10091W CP 10098W CP ...

Page 2: ...Spare Parts 6 Dimensions 7 Customer Care 8 specification Pressures The minimum recommended operating pressure is 0 5 bar For optimum performance a minimum operating pressure of 1 0 bar is recommended Temperatures Minimum hot water supply temperature 50 C Maximum hot water supply temperature 70 C Recommended hot water supply temperature 60 C Temperature adjustment range approximate 20 C 50 C Safety...

Page 3: ...w on the concealing plates hand tight 4 Position the washer on each of the nuts 5 Align the mixer and connectors and tighten the nuts using the special tool supplied Note Make sure that you do not damage the chrome plated surfaces when you tighten the nuts Installation Before you Begin 1 Make sure that the tap is installed by a competent installer 2 Turn off the water supply 3 The plumbing install...

Page 4: ...cealing plate over the threaded section of the column connectors 4 Apply a ring of sealant in accordance with the manufacturer s instructions underneath the concealing plates 5 Fit the mixer through the top of the bath 6 Install the washers and the locknuts Use a tap spanner to tighten the nut 7 Remove any excess sealant 1 2 Concealing Plate Locknut Washer Apply Sealant ...

Page 5: ...Use the special key provided to unscrew and remove the aerator 4 Turn on the hot and cold knobs and allow the water to run for approximatley one minute to remove any debris 5 Turn the hot and cold knobs to the off position and re install the aerator using the special key Operation Set the temperature by slowly turning the temperature selector right handle For safety reasons there is a stop that li...

Page 6: ...hen wiped dry using a soft cloth user Maintenance E8A525 CP Temperature Handle R29701241 Spline Adapter R8A532NF Aerator R8A526NF Fixed Stop E8A534CP Concealing Plates R29927969 Outlet Spare Parts R8A527NF Nut R8A528NF Thermostatic Cartridge Assembly E8A531 CP Divertor R8A530NF Ceramic Valve R29701241 Spline Adapter E8A529 CP Flow Handle R8A026NF Checkvalve and Filter E8A510 CP Concealing Plate R8...

Page 7: ... 1081774 W2 A dimensions All dimensions in mm 20max 150 15 G1 2 190 G1 2 Ø58 85 min 92 max 57 G1 2 57 105 208 180 65 G1 2 20max 150 15 G1 2 Ø58 90 max G1 2 83 max 10089W 10098W 10091W ...

Page 8: ...sed within a commercial business premise is guaranteed for 1 Year against any defect of materials or workmanship Not Covered by this Guarantee Damage or defects arising from incorrect installation improper use or lack of maintenance Installed product damaged in transit Consequential loss damage or product removal and installation costs General wear and tear This guarantee is in addition to your st...

Reviews: