3.4
LIGHTING THE APPLIANCE (MANUAL CONTROL MODELS)
a)
Turn on the gas isolation tap.
b)
Depress the control knob and turn anti-clockwise to the position
marked pilot. Hold in the control knob for a few seconds to purge the
pipe work.
c)
Continue to hold-in the control knob and press the igniter button. If the
burner does not light, continue to press the igniter button until ignition
occurs. Continue to hold the control knob for 5-10 seconds to allow the
thermocouple to heat up, if the pilot goes out when the control knob is
released, repeat the lighting sequence.
d)
Turn the control knob in the anti-clockwise direction to the high position
and the main burner will light.
e)
Turn the control knob clockwise to the low position and the gas input
will be reduced to the minimum setting.
f)
Slightly depress the control knob and turn to the pilot position, the main
burner will go out but the pilot will remain lit.
g)
Slightly depress the control knob and turn to the off position, the pilot
will now be extinguished.
3.5
LIGHTING THE APPLIANCE (SLIDE CONTROL MODELS)
a)
Turn on the isolation valve. Depress the control lever fully downwards
to the position marked. Hold down the control lever for a few seconds to
allow the gas to reach the pilot.
b)
The fire will then begin its ignition sequence. If the pilot does not light,
continue to press the control lever until ignition occurs. The pilot flame
can be seen by looking underneath the front ceramic rail, above the
burner heat shield, at the front left hand side of the fuelbed. When the
pilot has lit, continue to hold the control lever down for 5-10 seconds to
allow the thermocouple to heat up, before releasing the lever apply one
firm downwards push to ensure that the f.s.d. valve is fully latched, if
the pilot goes out when the control lever is released, repeat the lighting
sequence.
c)
After lighting, move control lever up to the high position and the main
burner will light. It is recommended that for the most efficient
performance the fire is allowed to warm up for a few minutes with the
the control lever set to high.
23