13
-
Output terminal
q
w
e
q
ERROR (Abnormal signal output)
a
a
-contact closed when the ION WIPER
stops abnormally.
Refer to「5. Operations」on page 15 for
cancelling the stop.
w
ION END (signal output of static electricity
removal)
a
a
-contact closed for approximately 0.2 sec.
when ionized air blow is finished. This
signal can be used for process control such
as counting number of operation times .
e
VAC START (Acctuation for external devices)
a
a
-contact closed between placing workpiece
and process completion. This can be used
for synchronized operation of external
devices to collect dust, etc.
a-contact (normally open)
24VDC, 2A MAX.
3-1. Major parts Name and Function
Internal contact circuit
Ionizer, compact blow type
(DTRY-ELL01)
Throttle valve (flow rate adjustment)
for air curtain
Power switch
Curtain pipe (for air curtain)
Note
Note: This does not supply ionized air.
Shower nozzle (outlet for ionized air)
Photoelectric switch
(workpiece detecting sensor)
Photoelectric switch
(workpiece detecting sensor)
pressure gauge
Regulator for Ionizer
Setting pressure range:
0.05 to 0.5MPa{0.5 to 5.0kgf/cm
2
}
Workpiece tray
Transparent anti-static cover
RESET button
Exhaust duct
Output terminal
(
a
-contact (normally open) 24VDC, 2A MAX.)
Air IN port
(φ8 quick fitting)
Selector switch for
Ionizer operating time
Throttle valve
(flow rate adjustment)
for Ionizer
(Back of the body)
(Front of the body)
Expanded metal
Summary of Contents for ION WIPER DTY-WC-L