— 8 —
Solenoid Valve F Series
EtherNet/IP Compliant
6-2
Use the DCHP server
This method acquires the IP address from the DCHP server. Use this if you are using a
large-scale network on which you cannot specify the IP address by using the host address
switches. You need a DCHP server on your network to use this method.
6-3
Upload from a flash memory
This method uploads the IP address from the internal flash memory. You can assign a fixed IP
address, but it is also possible to dynamically acquire it from a BOOTP server or DCHP server
because you can change the way of deciding the IP address. This is applicable if you want to
use a BOOTP server and operate on a large scale network.
To do the settings, use the software
*1
provided by the PLC vendor.
The factory setting for the switches is 000, so uploading from a flash memory is enabled
(acquiring the IP address from a DHCP server).
*1 BOOTP-DHCP Server (Rockwell Automation, Inc.)
Network Configurator (from Omron Co., Ltd.), etc.
DHCP server
Switching Hub
YS7M1
㻌