background image

Document No. BK-HV045

EtherNet/IP Compliant

Serial Transmission Compatible Manifold

Supported solenoid valves

F10 Series

F15 Series

User's Manual

Ver.4.0

Summary of Contents for YS7M1

Page 1: ...Document No BK HV045 EtherNet IP Compliant Serial Transmission Compatible Manifold Supported solenoid valves F10 Series F15 Series User s Manual Ver 4 0 ...

Page 2: ...ct names mentioned in this document are the trademarks of their respective companies This product does not have the appropriate functions to support applications such as safety equipment or accident prevention systems that require high levels of safety Do not put the communication cables near or in bundles with power lines This manual is for the F10 and F15 series solenoid valves Contact us if you...

Page 3: ...emory 8 7 Relationship between I O data allocation and solenoid valves 9 8 Network topology 10 8 1 Line format 10 8 2 Star format 10 8 3 Device level ring format 11 9 CIP class objects 11 9 1 Identity class code 01 hex 11 9 1 1 Service code 11 9 1 2 Attribute 12 9 1 3 Reset service 12 9 2 TCP IP interface class code F5 hex 13 9 2 1 Service code 13 9 2 2 Attribute 13 9 3 Ethernet Link class code F6...

Page 4: ...e 17 9 6 2 Attribute 17 9 6 3 About the number of outputs 18 9 7 System Information class code B0 hex 19 9 7 1 Service code 19 9 7 2 Attribute 19 10 Web page 20 10 1 How to use 20 11 Specifications 21 11 1 General specifications 21 11 2 Communication specifications 21 ...

Page 5: ...ess Network address Number for identifying a network itself Host address Number for identifying devices within a network BOOTP Bootstrap Protocol Communication protocol used by devices on a network to automatically acqoire IP addresses from a server DHCP Dynamic Host Configuration Protocol Protocol with expanded backward compatibility for BOOTP Connection Method for communications between devices ...

Page 6: ...cations are sent and received simultaneously Half duplex communication Communications in which receiving cannot be done while sending and sending cannot be done while receiving Auto negotiations Auto negotiation Function to automatically optimize communication method and communication speed with a connected party Default gateway Function that knows the method that packets are transmitted to other ...

Page 7: ...ng torque 0 22 to 0 25 N m 1 95 to 2 21 in lbf 24 24 VDC terminal G 24 VDC terminal FG Frame ground terminal FG terminal tightening torque 0 49 N m 4 34 in lbf Ground terminal connection connected internally to the FG on the power supply terminal 4 2 Indicator panel Display panel LED displays and descriptions The illustration shows the panel for the YS7M1 but the YS7M3 panel is the same Do not tur...

Page 8: ...a connection cannot be established H Holds the last output hold C Clears the output 1 1 Factory setting 4 3 2 Host address setting switch The host address setting switches can set the host address in the IP address Setting value Description 000 1 Sets the IP address according to the content of the flash memory Refer to 6 IP address settings for details 001 254 Sets the host address 255 999 Acquire...

Page 9: ...ress switches to set it directly This is because you can check the address settings visually and you do not need to do the settings via software or to use special equipment 6 1 Specify using the host address switches The range of IP addresses that can be set with the host address switches is shown in the table below NETWORK HOST IP address range 0 1 to 254 192 168 0 1 to 192 168 0 254 1 192 168 1 ...

Page 10: ...l flash memory You can assign a fixed IP address but it is also possible to dynamically acquire it from a BOOTP server or DCHP server because you can change the way of deciding the IP address This is applicable if you want to use a BOOTP server and operate on a large scale network To do the settings use the software 1 provided by the PLC vendor The factory setting for the switches is 000 so upload...

Page 11: ...to solenoid A only and are not wired to solenoid B because wiring is done according to specifications for the mounted valves This means that it cannot function as a double solenoid valve after it is delivered because no current flows to solenoid B even if it is switched from a single solenoid valve to a double solenoid valve When wiring specifications are W double wiring All wiring is for double s...

Page 12: ...nsecutive To use 10 consecutive use the YS7M3 Stations 8 7 6 5 4 3 2 1 Solenoids 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 8 Network topology The YS7Mn supports the following connection formats Line format Star format Device level ring format 8 1 Line format A line format network connects devices in a daisy chain format Switching hubs are not needed and the total length of the LAN cable can be reduce...

Page 13: ...bjects Name of object Class code Description Identity 01 hex Provides information that identifies a product TCP IP Interface F5 hex Provides the interface for the TCP IP network Ethernet Link F6 hex Provides information for the IEEE802 3 communications interface Device Level Ring 47 hex Provides information about the status of the device level ring Quality of Service 48 hex Provides information ab...

Page 14: ...s State of communications with devices WORD 1 6 Get Serial Number Number that identifies products of specific vendors UDINT 1 7 Get Product Name Product name SHORT_S TRING 1 8 Get State State of device 0 Nonexistent 1 Device Self Testing 2 Standby 3 Operational 4 Major Recoverable Fault 5 Major Unrecoverable Fault 255 Default Value USINT 9 1 3 Reset service Data Description 0 Executes the same ope...

Page 15: ...count 0 Discrete output point object Count Accumulated operating time 0 System information object Total power on time 9 2 TCP IP interface class code F5 hex 9 2 1 Service code Service code Name 01 hex Get_Attribute_All 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 9 2 2 Attribute Instance ID Attribute Access NV Name Description Data format 0 1 Get Revision Revision of TCP IP interface ob...

Page 16: ...or TCP IP network Structure IP Address IP address UDINT Network Mask Subnet mask UDINT Gateway Address Default gateway UDINT Name Server Primary name server UDINT Name Server 2 Secondary name server UDINT Domain Name Name of domain STRING 1 6 Get Set NV Host Name Name of host STRING 1 8 Get Set NV TTL Value Time to live for multicast USINT 1 9 Get Set NV Mcast Config Multicast address settings Str...

Page 17: ...e UDINT In Discards Number of incoming packets that were discarded UDINT In Errors Number of packets that had errors not counting the incoming discards UDINT In Unknown Protos Number of packets with unknown protocols UDINT Out Octets Number of octets sent UDINT Out Ucast Packets Number of unicast packets sent UDINT Out NUcast Packets Number of non unicast packets sent UDINT Out Discards Number of ...

Page 18: ...d Communication speed when full duplex mode is specified UINT 1 2 7 Get NV Interface Type Type of physical interface USINT 1 2 8 Get Interface State State of interface USINT 1 2 9 Get Set NV Admin State Whether interface is enabled or disabled USINT 1 2 10 Get NV Interface Label Name that identifies interface SHORT_S TRING 9 4 Device Level Ring class code 47 hex 9 4 1 Service code Service code Nam...

Page 19: ...ansport class 0 1 message USINT 1 8 Get Set NV DSCP Explicit Priority for UCMM CIP transport class 2 3 and other messages USINT 9 6 Discrete Output Point class code 09 hex 9 6 1 Service code Service code Name 0E hex Get_Attribute_Single 10 hex Set_Attribute_Single 9 6 2 Attribute Instance ID Attribute Access NV Name Description Data format 1 N 1 3 Get Set Value Output value 0 off 1 on BOOL 1 5 Get...

Page 20: ...s the output command goes from off to on The instance ID is the same as the solenoid number Refer to 7 Relationship between I O data allocation and solenoid valves for the relationship between the solenoid numbers and the I O data 1 1 2 2 3 4 3 5 6 4 7 8 5 9 10 Stations Solenoid instance ID RU GRXEOH VROHQRLGV ...

Page 21: ...TIME 1 101 Get Power on days units are days UINT 1 102 Get Power on hours units are hours UDINT 1 103 Get Power on minutes units are minutes UDINT 1 104 Get Power on seconds units are seconds UDINT 1 110 Get NV Total power on time Accumulated operating time LTIME 1 111 Get NV Total power on days units are days UINT 1 112 Get NV Total power on hours units are hours UDINT 1 113 Get NV Total power on...

Page 22: ...0 1 How to use You can check the internal status from the web page 1 Open a browser 2 Input the IP address of YS7Mn in the URL field The web page opens To check use Internet Explorer 7 or later Firefox 9 0 or later or Google Chrome 4 0 or later IP address of YS7Mn ...

Page 23: ... 4 4 compliant level 3 Insulation resistance 10 MΩ or more between all external terminals and the case using a 500 VDC insulation tester Standard CE marking compliant 11 2 Communication specifications Item YS7M1 YS7M3 Vendor ID 429 Output size 2 byte 4 byte Number of ports RJ45 2 Physical layer 10BASE T 100BASE TX CIP cyclic communications Connection Class 1 Exclusive Owner 1 RPI 1 1000 ms CIP exp...

Page 24: ...es office or the Overseas Department noted below 7 20 AB KOGANEI CORP PRINTED IN JAPAN KOGANEI CORPORATION OVERSEAS DEPARTMENT 3 11 28 Midoricho Koganei shi Tokyo 184 8533 Japan TEL 81 042 383 7271 FAX 81 042 383 7276 Website http www koganei co jp The specifications or the appearance of this product are subject to change any time without prior notice ...