III.  Cautions 

(1)  Avoid water pressure exceeding the specified value and cleaning with reverse flow, which will 

damage the sensor portion and cause failure.     

(2)  If measured fluid in the tube hole is frozen, the sensor portion may be damaged. If there is the 

possibility of freezing, take heat insulation measures. 

(3)  FM01 series including threaded portion is made of resin. Excessive tightening when fitting and 

unnecessary external force must be avoided.   

(4)  Do not hold the output cable when carrying the product. The soldered connection of the cable 

and electronic circuit may be damaged. 

(5)  The circuit portion must not be subjected to dew condensation. 

IV.  Insulation resistance/dielectric strength test 

The  insulation  resistance/dielectric  strength  test  must  not  be  conducted  because  there  is  the 
possibility of the electronic circuit being damaged. 

 Warranty 

1.  The contents of warranty 

 

  Warranty period 

   

The warrant period shall be one year after the shipment. 

 

  Warranty range 

 

If  a  malfunction  of  the product  you  purchased  occurs  because  of  our  responsible  reasons,  offer  of 

substitute or it will be charge-free repaired in our factory. But if a malfunction of the machine occurs 

due to the following reasons, even within the warrant period, it becomes the outside for a warranty.   

 

(a) Malfunctions due to erroneous applications, repairs or remodeling. 

        (Including the case in which the manufacturing specification differs from the application conditions.) 

(b) Malfunctions due to the falling after the purchase. 

(c) Malfunctions caused by natural disasters such as fire, earthquake, water disaster and lightning 

stoke, or riots or wars.     

(d) Malfunctions caused by mixing-in of foreign matters out of the piping. 

(e) Malfunctions caused by the peculiar problems due to combinations with other built in equipment. 

     

  In addition, a warranty here means the warranty of the product simple substance of our company. So 

the damage induced by failure of the products of our company shall be eliminated from the object of 

warranty. 

 

 

 

Summary of Contents for FM01 Series

Page 1: ...MJ400080F1 Small Karman Vortex Flow Meter FM01 Series Instruction Manual...

Page 2: ...ttention to the following points so that this flow meter can be used safely and accurately over a long period of time 1 The applicable fluid of this instrument should be liquid and industrial water in...

Page 3: ...period The warrant period shall be one year after the shipment Warranty range If a malfunction of the product you purchased occurs because of our responsible reasons offer of substitute or it will be...

Page 4: ...0102 4 to 40L min for FM0103 10 to 150L min for FM0105 and 25 to 250L min for FM0107 This instrument has no movable portion pressure loss is small output signal is proportional to the volume flow rate...

Page 5: ...mbient temperature 0 50 Supply voltage 12VDC or 24VDC Output 4 20 ADC Open collector MAX 10mA 30V DC FM0101 800Hz 4L m FM0102 800Hz 16L m FM0103 584Hz 40L m FM0105 900Hz 150L m FM0107 750Hz 250L m 4 2...

Page 6: ...MODEL DIAMETER FLOW RANGE FITTINGS LOW FLOW 0 5 4 L min R3 8 PT3 8 MALE MIDDLE FLOW 2 16 L min R1 2 PT1 2 MALE LARGE FLOW 4 40 L min R1 2 PT1 2 MALE LARGE FLOW 10 150 L min EQUAL TO ESLON UNION 25A LA...

Page 7: ...5 80 0 R1 2 FM0103 17 5 80 0 R1 2 FM0105 32 5 110 0 About 25A FM0107 30 0 105 0 R1 1 4 Caution in use Please be careful not to increase excessive clamping torque because the body and the mounting scr...

Page 8: ...10 8 6 4 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 FM0101 FM0102 FM0103 Flow L min Flow L min Output current mA FM0107 FM0105 Flow L min Flow L min 22 20 18 16 14 12 10 8 6 4 0 10 30 50 70 90 110 130 15...

Page 9: ...ly OFF Press SET for about 2 seconds Select mode by pressing or Press SET Set the set value by pressing or Press SET Select mode by pressing or Press SET Set the set value by pressing or Press SET Set...

Page 10: ...og output line Set ammeter output value when analog output FS by pressing or Press SET Set to actual flow device and supply 100 FS corresponding flow Set ammeter output value when flow 100 FS by press...

Page 11: ...min In case of gal min 2 Setting of output zero Set 4 mA by pressing either one Alternate indication Example In case of L range Supplying FS flow with actual flow device 3 Setting of output span 4 Set...

Page 12: ...MJ400080F1 URL http www kofloc co jp...

Reviews: