FJ400062B1 

Created on 2021/12/20 

- 3 - 

 

3)

 

Model 2420 is equipped with a packing for fixing the shaft to the needle shaft.    In 
order to maintain this shaft anti-shake function, do not forcibly rotate in the 
opening direction beyond the contact position when the valve is fully opened. 
 

4)

 

Practical evaluation is recommended for low flow rate.   

Model 2412 series is most suitable for high precision flow rate adjustment. 
Please be careful when the reference flow rate is as follows; 

Gas: 1L/min or less, Liquid: 50mL/min or less 
 

5)

 

If you turning the hexagon nuts of the inlet-side connection counterclockwise 
strongly, the fitting screw of the hexagon nuts will loosen from the main body 
block, and it may cause external leakage. 
Your attention is required when removing the installed joints. Please fix this 
hexagon nuts with a wrench and be careful not to apply a load to the body when 
removing the joint. 
Should the needle part is loosen, tighten it to the body with a torque of 4 N·m. 
 

6)

 

This product is assembled with oil-free specifications without using any greases. 
However, it is not a particle-free product because it is not assembled in a clean 
room. Therefore, when using the product with strict prevention of contamination, 
such as at food production lines, we recommend that you clean and purge the 
inside of this product before installation. 
No grease or lubricating oil is used for the rotating screw also. Therefore, if the 
rotation is repeated continuously, heat is generated in the screw part, and the 
rotation gradually becomes harder. If the rotation is continued, the screw part 
may seize and the flow rate may not be adjusted. There is no problem with minute 
adjustment, but please note that continuous use of large rotations is not 
recommended. 
If you change the purge setting repeatedly, such as flow closed, flow control or full 
open, please select MODEL2412 or MODEL2400. 
 
 
 
 
 
 
 
 

Summary of Contents for 2420

Page 1: ... using your new needle valve please read this manual thoroughly to ensure the valve will operate to its maximum performance The contents of the manual are subject to change without prior notice The manual has been carefully created and checked before shipment If you notice any deficiencies errors or omissions however please inform us The warranty period of the needle valve is one year from the dat...

Page 2: ...aching the knob to the shaft align the knob protrusion with the flat end of the shaft and insert as shown below 3 How to use 3 1 Control of Flow Turn the knob of the needle valve to control the flow Turning it counterclockwise OPEN will increase the flow and clockwise CLOSE will decrease the flow 3 2 Precautions 1 When storing the needle valve at your premises installing it in a line removing it f...

Page 3: ...ul not to apply a load to the body when removing the joint Should the needle part is loosen tighten it to the body with a torque of 4 N m 6 This product is assembled with oil free specifications without using any greases However it is not a particle free product because it is not assembled in a clean room Therefore when using the product with strict prevention of contamination such as at food prod...

Page 4: ...te H2O 0 1MPa Minimum Flowrate H2O 0 1MPa Zero stop H2O 0 1MPa When shipping N1 26L min 0 2L min Within about 20mL min 0 87L min 10mL min Within about 1mL min N2 40L min 1L min 1 38L min 30mL min N3 92L min 1 5L min 2 7L min 50mL min N4 112L min 5L min 3 3L min 150mL min N5 182L min 5L min Within about 2L min 4 2L min 150mL min Within about 80mL min CV value The flow rate is based on AIR conversio...

Page 5: ...ed to the product is the needle number The number of dots machined on the flat surface of the shaft under the knob indicates the needle number As shown in the photo 2 2 dots are N2 left side 3 dots are N3 right side and N5 not shown in the photo has 5 dots Cut out dimensions Φ15 N2 N3 Photo 1 Lot Number Label The 2nd number from the right is the needle number Photo 2 Dots on the Shaft The number o...

Page 6: ...e of warranty If the KOFLOC product fails during the warranty period due to a cause attributable to KOFLOC KOFLOC shall at its option and expense provide a replacement product or repair the failed product at the KOFLOC factory This warranty however shall not cover damages due to a cause not attributable to KOFLOC opportunity loss lost profit secondary disaster accident compensation suffered by the...

Page 7: ...rporated equipment f Other failures and damages which are considered not attributable to KOFLOC Please be aware that the warranty shall not cover opportunity loss suffered by you or your customer or damage to other equipment or any other damages due to a failure of the KOFLOC product URL http www kofloc co jp ...

Reviews: