Koehler K12212 Operation And Instruction Manual Download Page 9

K12212 / K12219 12-Unit Oxidation Bath 

Operation and Instruction Manual 

 

K12212-Manual 

 

 

-

7-

 

 

3.2  Unpacking 

 

Carefully  unpack  and  place  the  instrument  and 

accessories  in  a  secure  location.  Ensure  that  all 
parts listed on the packing list are present. Inspect 
the  unit  and  all  accessories  for  damage.  If  any 
damage  is  found,  keep  all  packing  materials  and 
immediately  report  the  damage  to  the  carrier. We 
will assist you with your claim, if requested. When 
submitting  a  claim  for  shipping  damage,  request 
that the carrier inspect the  shipping container and 
equipment. Do not return goods to Koehler without 
written authorization.  

 

3.3  Setup 

 

Equipment Placement.

 Place the instrument on a 

firm,  level  table  in  an  area  with  adequate 
ventilation  or  in  a  hood.  The  unit  may  be  leveled 
by  making  minor  turning  adjustments  to  the  feet 
located  at  the  base  of  the  unit.  Please  note  that 
Koehler  does  not  supply  a  level  with  this 
equipment. 
 

Ventilation.

  A  fume  hood  or  exhaust  system  is 

required  when  operating  the  unit.  Flammable 
vapors  and/or  steam  are  generated  during 
operation  and  must  not  be  permitted  to 
accumulate.  A  canopy-style  hood  may  be  used  if 
the height from the top of the unit to the canopy is 
5  feet  or  less.  The  exhaust  blower  should  have  a 
rating of 1000 C.F.M. or greater. 
 

Power. 

Connect  the  line  cords  to  properly  fused 

and grounded receptacles with the correct voltage 
as  indicated  in  section  1.3  or  on  the  back  of  the 
unit.  
 

WARNING:

 

For  safety,  disconnect  the  power 

when 

performing 

any 

maintenance 

and/or 

cleaning.

 

Do 

NOT

  turn  the  power  on  unless  the 

bath  is  filled  with  the  proper  medium;  otherwise, 
damage  may  occur  to  the  unit  and  the  warranty 
will be void. 
 

Air Supply Requirement. 

This unit requires an air 

source  capable  of  supplying  a  flow  rate  of  94 
mL/min  per  test  cell.  The  air  should  be  free  from 
moisture,  oil,  and  particulate  matter.  A  drying 
tower  should  be  incorporated  to  remove  any 
contaminants. Air inlet pressure should not exceed 
10 psi.  
 

NOTE:

  Koehler  Instrument  does  not  supply  air 

source required for running instrumentation.  

 

3.4  Software Installation 

 

1. 

Installation. 

Insert  the  CD-ROM  into  the  CD 

tray  of  the  PC.  The  CD  should  automatically 
display  the  setup  screen.  If  this  does  not 
happen within 10 seconds, browse the files on 
the CD-ROM and double click on the setup file 
(setup.exe)  to start  the  installation.  Follow  the 
instructions  on  the  screen  to  setup  the 
software.  The  software  is  ready  to  run  once 
the installation has been completed.  
 

NOTE

:  When  first  installed,  the  software  is  in 

demo mode, it must be registered  in  order for 
the software to work with the unit. 

 
2. 

Registration.

  Start  the  program  and  then  go 

to  >>  Help  >>  Register.  A  registration  screen 
will  appear  with  a  registration  number  (Refer 
to  Figure  1,  below).    E-mail  Koehler  at 
[email protected]  or  call  with 
the  registration  number  for  the  unlock  code. 
Once  the  software  has  been  registered,  it 
must be restarted before tests are run. 

 

 

 

Figure 1. Registration Screen 

 
3. 

Communication  Port  Cables. 

Using  the 

communication  port  cables  supplied  for  the 
Oxidation  Stability  Unit,  connect  the  RS232 
ports located on the unit to the communication 
ports on the PC.  

 
 
 
 
 

 

Summary of Contents for K12212

Page 1: ...Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analys...

Page 2: ......

Page 3: ...he applicable standards set forth in this certification Specifications ASTM D943 ASTM D2274 ASTM D2893 ASTM D4310 ASTM D6158 ACOS CD12 57 DIN 51586 DIN 51587 ISO 4263 ISO 12205 NF M 07 047 NF T 60 150...

Page 4: ...K12212 K12219 12 Unit Oxidation Bath Operation and Instruction Manual K12212 Manual 2...

Page 5: ...r Running Tests 8 4 3 Temperature Controller Operation 9 5 Operation 10 5 1 Bath 10 5 2 Power 11 5 3 Oxidation Cell Assembly 11 5 4 Flowmeter Calibration Procedure 11 5 5 Flowmeter Calibration Data 11...

Page 6: ...K12212 K12219 12 Unit Oxidation Bath Operation and Instruction Manual K12212 Manual 4 11 Warranty 16 12 Returned Goods Policy 17 Notes 18...

Page 7: ...nstrument service to better understand your requirements and provide you with the best solutions You can depend on Koehler for a full range of accurate and reliable instrumentation as well as support...

Page 8: ...s prior to use Equipment Modifications and Replacement Parts Any modification or alteration of this equipment from that of factory specifications is not recommended voids the manufacturer warranty pro...

Page 9: ...performing any maintenance and or cleaning Do NOT turn the power on unless the bath is filled with the proper medium otherwise damage may occur to the unit and the warranty will be void Air Supply Req...

Page 10: ...e bath medium for bath temperature uniformity 8 Oxidation Test Cell Assembly Oil Sample is placed within oxygen test tube and is contacted with oxygen in the presence of water and an iron copper catal...

Page 11: ...umber Description K122 0 18 Oxygen Delivery Tube K122 0 19 Oxidation Test Tube K122 0 20 Condenser 250 000 40C ASTM 40C Thermometer Range 72 to 126 C For ASTM D2893 Part Number Description K12212 D289...

Page 12: ...automatically store the value The lower green display will stop flashing If further adjustments are necessary press the Program Key again Resume regular operations by pressing the Exit Function key t...

Page 13: ...strument it is necessary to have an additional Calibrated and Certified Flowmeter capable of reading the air flow rate for your desired range 1 Connect the air source to the Calibrated and Certified F...

Page 14: ...r K12212 K12219 12 Unit Oxidation Bath is equipped with Over temperature Protection OTP circuitry which prevents the unit from exceeding unsafe operating temperatures If the unit cannot maintain the s...

Page 15: ...03 036 RTD Temperature Safety Limit 120V 275 103 037 RTD Temperature Safety Limit 230V 278 001 002 Slow Blow Fuse 1A 5x20 mm 278 040 001 Time Delay Fuse 40A 278 030 002 Time Delay Fuse 30A 600VAC 278...

Page 16: ...K12212 K12219 12 Unit Oxidation Bath Operation and Instruction Manual K12212 Manual 14 Wiring Diagrams 8 1 K12212 Unit Wiring...

Page 17: ...K12212 K12219 12 Unit Oxidation Bath Operation and Instruction Manual K12212 Manual 15 8 2 K12219 Unit Wiring...

Page 18: ...K12219 12 Unit Oxidation Bath should not require service Any service problem can be quickly resolved by contacting Koehler s technical service department either by letter phone fax or email In order...

Page 19: ...tem s to be returned and the reason for the return You will be issued a Returned Authorization RA number which must be prominently displayed on the shipping container when you return the material to o...

Page 20: ...K12212 K12219 12 Unit Oxidation Bath Operation and Instruction Manual K12212 Manual 18 Notes...

Reviews: