Chapter 3 Installation Method MDC-7000P/7900P
Series
3-32
0092669006-05E
3.4.8 Cable connection for inter-switch
3.4.8.1 Cable connection instructions for cross-over, dual and independent
connection
In case of a dual, cross-over, or master/slave connection using two sets of radar system or Display
unit, the remote cable and data cable are connected as shown in the figure 3.21.
(1) The heading, speed and latitude/longitude signals input to the data connector of master Display
unit and are supplied to the slave Display unit via remote cable. The slave Display unit can also
use ATA and chart option functions in the same way as the master one.
(2) Connect the slave Scanner unit to the slave Display unit in a crossover connection.
(3) Operation unit (MRO-108P) is required for MRD-108P.
Master Display unit
(MRD-108P/MRM-108P)
J7
Slave Display unit (MRD-108P/MRM-108P)
Connect slave Antenna
unit to slave Display unit in
the case of crossover
connection.
Data cable
SD05-1973 xxM
Figure 3.21 Connecting a slave Display unit on Crossover, dual and independent connection
Remote cable
CW-561-10M or 30M
(10m or 30m)
The device connected with radar must be
compliant with the following resolutions.
SDME: Resolution MSC.96 (72)
GPS: Resolution MSC.112 (73)
DGPS: Resolution MSC.114 (73)
THD: Resolution MSC.116 (73)
J8
J8
J3
J3
JB-35
JB-35
Summary of Contents for MDC-7000P series
Page 1: ......
Page 2: ......
Page 56: ... This page intentionally left blank ...
Page 90: ... This page intentionally left blank ...
Page 116: ... This page intentionally left blank ...
Page 146: ... This page intentionally left blank ...
Page 147: ...0092669006 05E A 1 INTER CONNECTION DIAGRAM RB808P ...
Page 148: ...A 2 0092669006 05E INTER CONNECTION DIAGRAM RB809P ...
Page 149: ...0092669006 05E A 3 INTER CONNECTION DIAGRAM MRD 108P MRO 108P ...
Page 150: ...A 4 0092669006 05E INTER CONNECTION DIAGRAM MRM 108P MRO 108P ...
Page 151: ......
Page 152: ......