
Chapter 8
MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series
Trouble Shooting And On Board Servicing
Operation Manual
8-18
93142122-07
8.4 On board servicing
8.4.1 Replacing the fuses
There are three fuses provided on the processor unit. Details are as follows:
z
Fuse type and ratings
Fuse name
Shape (Dimensions in mm)
Fuse Type
Ratings
Main fuse
Tubular type (
φ
6.3 x 32)
Normal Blow
15 A
Modulator fuse
Tubular type (
φ
5 x 20)
Normal Blow
0.3 A
Drive Motor fuse
Tubular type (
φ
5 x 20)
Normal Blow
5 A
z
Location of the fuses
Figure 8.2 Fuses provided on the Processor
Processor unit
SCANNER
DATA 1 DATA 2 DATA 3
AIS
REMOTE
MAIN
GYRO
Modulator fuse
Drive Motor fuse
Main fuse