Chapter
7
KGC-1
Technical References
Operation Manual
7-6
0093121652-04
7.3 Setting the Status switch
WARNING
Setting of the status is not necessary in normal operation.
When a need is arisen, take due care for correct setting.
The following functions can be set on the status switch in the Processor unit.
Switch
element
No.
Functions ON OFF
1
DGPS data selection
WAAS
RTCM SC-104
2
For technical use (Keep OFF)
×Resetting prohibited
Keep OFF
3
Bit rate of bearing output
38400 baud
NMEA0183 (4800 baud)
4
Selection of backup period for
interruption to calculate bearing
60 sec
0 sec
5 Datum
selection
Tokyo
WGS84
6
Limits of elevation angle
5 degree
20 degree
7
Initialization (Cold start) Initialized
Not
initialized
8
For technical use (Keep OFF)
×Resetting prohibited
Keep OFF
The status switch setting is defaulted to OFF.
CAUTION: When resetting the status switch, be sure to turn off the unit.
CAUTION: The initialization (Cold start) is completed by setting the switch element No.7 to ON and
after about 10 seconds, turn the unit off and reset the No.7 to OFF. If the switch element No. 7 is left
to ON, the unit will be initialized each time the unit is turned on.
Status switch
Fig 7.1
The location of the Status switch in KGC-1 Processor unit
OFF
ON
1 2 3 4 5 6 7 8