Kodak V2CS Technical Data Manual Download Page 3

KODAK VISION2 Color Negative Control Strips, Technical Data and Crossover Information

3

KODAK VISION2 Color Negative Control Strips

Introduction

KODAK VISION2 Color Negative Control Strips (Figure 1) 
are intended for the control of Process ECN-2 using the 
procedures described in KODAK Publication No. H-24, 
Manual for Processing KODAK Motion Picture Films, 
Module 1, Process Control

The first batch of KODAK VISION2 Color Negative 

Control Strips is code 5011 for 35 mm, CAT 152 0469 and 
code 5012 for 16 mm, CAT 152 0444.

Figure 1 Processed Control Strip - 35mm

F009_0146CC

Steps

9071

ECN-2

21

14

8

4

MD

D-min

LD

HD

Important Improvements

KODAK VISION2 Color Negative Control Strips 
incorporate several important improvements into the control 
strips for Process ECN-2.

• A VISION2 emulsion is being used for process control. 

The new format is exposed on KODAK VISION2 200T 
Color Negative Film 5217, while the former ECN control 
strip was exposed on KODAK VISION 200T Color 
Negative Film 5274.

KODAK VISION2 Color Negative Control Strips, 

Process ECN-2, are packaged in 100-foot rolls containing at 
least 120 exposures and a processed reference strip. The 
exposures on the roll are spaced at 9.5-inch intervals. Each 
exposure has 21 gray-scale steps at 0.20 log H increments 
(2/3 camera stop). 

 The reference strip accompanying each roll was exposed 

along with all other control strips; it was then processed 
under specified well-controlled conditions. An instruction 
sheet enclosed with the package contains process deviation 
(correction) factors, if they are required, to determine your 
laboratory process aim numbers. A four-digit code number 
appearing on the carton, can, control strips, reference strips, 
and instruction sheet, identifies each production batch of 
strips.

Summary of Contents for V2CS

Page 1: ...Eastman Kodak Company 2004 V2CS August 2004 KODAK VISION2 ColorNegative Control Strips Process ECN 2 Technical Data and Crossover Information...

Page 2: ...274 5 ECN 2 Control Strip Exposed on KODAK VISION2 200T Color Negative Film 5217 6 Effects of Mechanical and Chemical Variations 7 Developer Mechanical Factors 8 Effects of Time and Temperature Variat...

Page 3: ...ulsion is being used for process control The new format is exposed on KODAK VISION2 200T Color Negative Film 5217 while the former ECN control strip was exposed on KODAK VISION 200T Color Negative Fil...

Page 4: ...Negative Film 5217 Physically the center to center step distance has been maintained on the new control strips no problems should be encountered with existing automatic densitometers Once the transiti...

Page 5: ...Data and Crossover Information 5 Figure 2 ECN 2 Control Strip Exposed on KODAK VISION 200T Color Negative Film 5274 0 0 1 0 2 0 3 0 4 0 3 0 2 0 1 0 0 0 1 0 2 0 Densitometry Exposure Process ECN 2 1 5...

Page 6: ...l Data and Crossover Information Figure 3 ECN 2 Control Strip Exposed on KODAK VISION2 200T Color Negative Film 5217 Exposure 1 50 sec Process ECN 2 Densitometry Status M 0 0 1 0 2 0 3 0 4 0 3 0 2 0 1...

Page 7: ...level for the variable is represented by zero density The magnitude of the changes shown in these plots should not be considered to be process control limits Also the data presented are qualitative no...

Page 8: ...320 F Time 5217 20 10 15 25 05 0 05 15 20 25 10 20 10 15 05 0 10 05 AIM STRIP CODE NO REFERENCE VALUES RED B W BLUE GREEN B W BLUE GREEN RED 240 220 340 15 10 20 0 05 05 300 240 10 0 05 220 05 10 10 3...

Page 9: ...H 5217 20 10 15 25 05 05 0 10 20 15 25 15 20 05 10 0 VALUES REFERENCE CODE NO AIM STRIP GREEN BLUE RED B W GREEN BLUE RED 10 20 15 10 0 05 05 10 10 05 0 05 10 15 10 05 10 45 10 25 10 15 10 05 10 35 10...

Page 10: ...2 1 4 0 8 1 6 1 0 1 2 1 4 0 8 NaBr 5217 20 15 10 25 05 05 0 10 20 15 25 15 20 05 10 0 VALUES CODE NO REFERENCE STRIP AIM BLUE GREEN RED B W RED BLUE GREEN 10 20 15 10 0 05 05 10 10 05 0 05 g L 10 B W...

Page 11: ...Na 5217 20 10 15 25 05 05 0 10 20 15 25 15 20 05 10 0 VALUES REFERENCE CODE NO AIM STRIP GREEN BLUE RED B W GREEN BLUE RED 10 20 15 10 0 05 05 10 10 05 0 05 3 0 2 0 1 5 1 0 2 5 10 B W GREEN RED B W BL...

Page 12: ...0 150 0 50 0 0 0 100 0 mL L 200 0 50 0 100 0 mL L 150 0 0 0 200 0 100 0 150 0 PB C1 5217 20 10 15 25 05 05 0 10 20 15 25 15 20 05 10 0 REFERENCE CODE NO STRIP VALUES AIM GREEN BLUE RED B W GREEN BLUE...

Page 13: ...5 10 B W BLUE GREEN g L Substitute CD 2 for CD 3 5274 05 BLUE GREEN RED B W BLUE B W GREEN RED B W 10 1 5 0 0 0 5 g L 1 0 2 0 0 0 0 5 05 05 0 10 10 05 05 0 10 20 15 10 GREEN BLUE RED B W GREEN BLUE RE...

Page 14: ...cess ECN 2 Developer HD LD D Min LD 0000 HD MD 10 0 05 RED 05 10 B W BLUE GREEN mL L 5274 BLUE B W GREEN RED BLUE GREEN B W RED mL L 4 0 10 10 05 05 0 10 0 0 2 0 05 05 0 20 10 15 6 0 RED BLUE GREEN B...

Page 15: ...l Rinse mL L 300 100 200 0 mL L F 34a Fixer 5217 20 10 15 25 05 0 05 15 20 25 10 20 10 15 05 0 10 05 AIM STRIP CODE NO REFERENCE VALUES RED B W BLUE GREEN B W BLUE GREEN RED 0 75 15 10 20 0 05 05 0 25...

Page 16: ...5 RED 05 10 B W BLUE GREEN 5274 2 5 mg L 05 RED GREEN BLUE B W BLUE B W RED GREEN B W 10 5 0 mg L 0 0 2 5 7 5 0 0 05 05 0 10 10 05 05 0 10 15 20 10 RED BLUE GREEN B W RED BLUE GREEN AIM STRIP VALUES C...

Page 17: ...6 25 6 15 6 5 6 45 6 35 6 25 6 HD LD D min LD MD HD 0000 2 Na S Bacterial 5217 20 10 15 25 05 05 0 10 20 15 25 15 20 05 10 0 REFERENCE CODE NO VALUES STRIP AIM GREEN BLUE RED B W GREEN BLUE RED 10 20...

Page 18: ...y the new batch trends as compared to the previous batch this is a normal batch to batch variation and is to be expected If you are unable to maintain a plot within your action limits with the new con...

Page 19: ...ord Form H 24F Control Strip Crossover Process ECN 2 DATES GREEN B W BLUE GREEN GREEN B W RED RED BLUE B W BLUE RED 05 10 0 CB control 0 08 CB action 0 06 CB control 0 09 CB action 0 07 10 10 05 10 0...

Page 20: ...DAK Publication No V2CS MORE INFORMATION Outside the United States and Canada please contact your Kodak representative You can also visit our web site at www kodak com go motion for further informatio...

Reviews: