Additional Calibration Information
C-24
October 2002
Editing Information on the Density Source Tab
The Density Source tab specifies how the calibration application is to receive
density data. The values displayed in the example are the default settings.
To edit the configuration information on the Density Source tab:
1.
Use the drop-down lists to change the Density Source information as needed.
2. If you have completed all editing of configuration information (including
information on the other tabbed screens), click
OK
to save the changes and
close the Edit Configuration screen.
NOTE:Click
Cancel
to cancel all changes made to the Edit Configuration screen
and close the Edit Configuration screen.
3. To continue making changes to the Edit Configuration, click on another tab
and make changes as needed.
Density Source
Attribute
Description
Density Source
Indicates the source (densitometer or file) of the density data.
Density Source Port
Indicates the name of the RS-232 port that the densitometer is
connected to. This port is the source of the density data. The name of the
port is specific to the computer system platform.
Density Source File
Indicates the filename for the source of density data. This is only used if
the Density Source is a file. If you designate a file as the density source,
this is the file name you use for “Creating a Density File for Use with
Calibration” on page C-32.
Summary of Contents for Professional RP 50
Page 1: ...KODAK PROFESSIONAL RP 50 LED Printer Operator s Guide Part No 2J0686 ...
Page 16: ......
Page 74: ......
Page 90: ......
Page 118: ......
Page 122: ......
Page 146: ...Additional Calibration Information C 12 October 2002 Value Graph ...
Page 147: ...Additional Calibration Information October 2002 C 13 Difference Graph ...
Page 168: ......
Page 190: ......
Page 197: ......