Cleaning and Maintenance

For detailed cleaning and replacement procedures, see the 

Maintenance

 chapter in the User’s Guide.

Opening/closing the scanner cover

1. Turn off the scanner.
2. Lift up the scanner cover release to unlatch the 

scanner cover.

3. Pull up to open the scanner cover.
4. Close the door when finished cleaning internal 

components or replacing parts.

5. Turn on the scanner.

FEED MODULE
Cleaning and replacing the feed module

1.

Open the scanner cover.

2.

Push against the raised edge on the left side of the 
front roller cover to the side and pull the cover up and 
out to remove it.

NOTE: You may need to lift the input tray slightly to remove 

the front roller cover.

3. Remove the feed module by pushing it to the right and 

lifting it out.

4. Manually rotate and wipe the feed module rollers with a 

roller cleaning pad.

5. Inspect the feed module. If the feed module tires show 

signs of wear or damage, replace the tires or the feed 
module.

6. Remove any dust or debris from the tray area under the 

feed module and front roller cover.

7. Insert the new feed module by aligning the pins and 

pushing it toward the right to fit it into position.

8. Reinstall the front roller cover.

SEPARATOR MODULE

Cleaning and replacing the separator module 

1. Open the scanner cover.
2. Grasp the separator module and lift it up and out of 

position.

 

NOTE: The separator module fits tightly in place, 

therefore, you may need to pull hard to release 

it. 

3. Manually rotate and wipe the separator module tires 

with a roller cleaning pad.

4. Inspect the tires. If the separator tires show signs of 

wear or damage, replace the tires or the separator 
module.

5. Insert the new separator module and align the shaft 

ends.. 

6. Press until the separator module clicks into place.

PAPER PATH

1. Remove the wrapping from the Transport Cleaning 

Sheet.

2. Adjust the side guides to fit the cleaning sheet.
3. Feed the cleaning sheet (adhesive side up) through the 

scanner in portrait orientation until all residue is 
removed from the drive rollers.

4. Adjust the sides guides to fit, feed the cleaning sheet 

(adhesive side up) through the scanner in landscape 
orientation until all reside is removed from the drive 
rollers.

5. Using the same cleaning sheet, repeat Steps 3 and 4, 

but feed the cleaning sheet through the scanner 
adhesive side down until all reside is removed from the 
drive rollers.

NOTE:  When the cleaning sheet gets dirty, discard it and 

use a new one.

IMAGING GUIDES
Cleaning the imaging guides

Clean the exposed (top side) surfaces of the imaging 

guides. You do not need to remove the imaging guides for 

cleaning unless there is dust or dirt on the underside of the 

imaging guide.
1. Open the scanner cover. 
2. Allow the scanner to cool, with the lamps off, for 5 

minutes before proceeding.

3. Wipe the upper and lower imaging guides with a 

Staticide wipe.

NOTE:  The i1410 Scanner does not have an upper 

imaging guide.

4. Dry the imaging guides with a dry Staticide wipe.
5. Lower the scanner cover and press it down firmly until it 

latches into place.

To do a more thorough cleaning, remove the imaging 

guides. Refer to the instructions in the 

Maintenance

 

chapter of the User’s Guide.

IMPORTANT:

The Roller Cleaning Pad contains sodium lauryl ether 
sulfate and sodium silicate which can cause eye 
irritation. 

S

taticide wipes contain isopropanol which can cause 

eye irritation and dry skin. Wash your hands with soap 
and water after performing maintenance procedures. 

Refer to the User’s Guide for MSDS acquisition.