SETTING UP (Continued)
ADJUSTING THE BURNER
Allow sufficient air to obtain a clean looking flame by loosening the lock screws and moving the air shutter, and if
necessary, the bulk air band.
DRAFT CONTROL ADJUSTMENTS
The unit is set up in the factory to burn cleanly into atmospheric conditions. Therefore if a chimney is fitted to the
machine, an "O" draft would be the optimum condition.
FINAL AIR-ADJUSTMENTS
Allow at least ten minutes for warm-up, and longer if the unit is new, in order to burn off the oil deposits on the
heat exchanger and other surfaces. Check and adjust all controls. (See Manufacturer’s Instructions sheets.) Test
the primary control Safety Switch to insure a safety shutdown will occur in the event of equipment malfunction.
NOTE
- The settings below have already been completed for this unit, so the following instructions for adjusting
apply only if a new burner or coil is installed.
OPERATION
STARTING THE PRESSURE WASHER
1.
Make sure that the burner switch is "OFF", and that all other switches are in the "OFF" position.
2.
Connect water supply to the Washer.
( .
Pick up spray gun and hold it firmly, and pull on the gun trigger to evacuate all air in the system.
) .
Release gun trigger.
STARTING THE ENGINE
1.
Hold securely and open the Trigger Gun to reduce the load on the engine.
2.
Turn the Engine Switch on.
( .
Start Engine.
) .
Advance the throttle to bring the engine to full speed.
Caution - The force of the water leaving the nozzle causes a kick-back or recoil at the trigger gun.
BURNER START UP
Turn Burner Switch to "ON".
SEE PAGE 5 FOR DETAILED BURNER START UP INSTRUCTIONS.
WARNING
- Do not use gasoline, crankcase oil, any oil-containing gasoline, or any other volatile substance.
CAUTION
- Do not run the fuel pump dry. Always check the fuel level in the tank before running the washer.
4
GF