Deletion of all RF cards.

Press “SET” button. (Please refer to “initial operation of set button.”)
Press “SET”           button again so that indicator displays “C.dEL.”
To delete, press “Cancel”              button. 
Tone sound of the deletion of all RF card IDs is heard (once for 60 seconds). When deletion is completed,
tone sound stops. 

Lobby Phone ID change (Password setting)

Press “SET” button. (Please refer to “initial operation of set button.”) 
Indicator shows “Lb.id.”
Input new password and press “#” to finish password registration (2 digits only). 

Registration tone sound is heard. 
(System administrator designates system password lest users change lobby phone ID.)

- In case of installing lobbyphone more than 1pcs, each ID of lobbyphone should be resistered differently.
- In order to use monitoring function of lobbyphone which has lobby mornitoring function, 

the lobbyphone’s ID should be set as “1”.(This function is available only for KLP-100 series.)

Lobby Phone version check

Press “SET” button. (Please refer to “initial operation of set button.”)

Press “Set” button           again so that indicator displays “VER.”

Press “ Cancel”           button, indicator displays “02.07”

How to set Lobby Phone (initial operation of set button) 

Press “SET”button. 
Input 4-digit system password (default password:”9999”) and press “#”

- Only up to four ciphers are available for password.

How to change password of lobbyphone.

Press “SET” button. (Please refer to “initial operation of set button.”)
Pressing ‘SET’ button           again until ‘Lb.PS.’ sign emerges on display. After pressing ‘Cencel’ button          , 
if you input new password and press ‘#’ button, then the password is registered.
ex) When making password ‘9999’ changed into ‘1111’.

Registration of Lobby Phone (KLP-100 series) RF-ID Card (Card Registration)

optional 

Press “SET” button. (Please refer to “initial operation of set button.”) 
Press “SET” button         again so that indicator displays “RF.id.”

a) Press ‘Cancel’ button          , then ‘In’ sign emerges and changes to ‘0’ sign at interval of a second. 

At this time, contact the card to lens part. (1 time)
Registration tone sound is heard (twice). Indicator displays “1.”

b) Contact the card to lens part (once). 

Registration tone sound is heard. Indicator displays “0002.”

c) Contact the card to lens part (once). 

Registration tone sound is heard. Indicator displays “Oh-.”

Registration of a card is completed. ->  Completion tone sound is heard (four times).

- In order to register a card, the card should be contacted to lens part total 3 times. 

Operational Descriptions 

SET

SET

Button                  Hold               Resistered password                                # button     Setting mode

Setting mode    Lobbyphone ID setting mode    button                Existing ID               Hold mode                    Input  new ID              button

SET

Setting mode       Lobbyphone RF setting mode       button                               ID input  hold state

Lobbyphone password setting mode       button          Existing password             New password           ‘#’ button

RF card delete mode             button           Deleting card number

SET

Mode identifying lobbyphone version   Identified version

Summary of Contents for KDP-100

Page 1: ...spection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases will be subject to charge even during warranty period a Breakdown during transport or through careless treatment by consumer b Breakdown cause by unauthorized repair or system modification c Breakdown cause...

Page 2: ...he product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully an...

Page 3: ...o sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places ...

Page 4: ...ces should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdown...

Page 5: ...button in order guardroom KIP 120 is called House Main Line Terminals Adopt terminal type for easier connection to main house line 1 17V 2 GND 3 Voice 1 4 Voice 2 5 Video 6 Data 7 Door Power FND indicator Characters are displayed when setting or calling to house Component s Name Precautions for Operation Keep away from humidifier and stove High temperature and humidity may cause troubles Do not dr...

Page 6: ...th house Pressing 0 0 during the call with house _______ is displayed Input new password and press button ex In case registering 1111 as password Only up to four ciphers are available for password Door open using lobby phone with password In order to open the door by password from lobby press house number password then the door is automatically released ex In case opening common gate by password r...

Page 7: ... password of lobbyphone Press SET button Please refer to initial operation of set button Pressing SET button again until Lb PS sign emerges on display After pressing Cencel button if you input new password and press button then the password is registered ex When making password 9999 changed into 1111 Registration of Lobby Phone KLP 100 series RF ID Card Card Registration optional Press SET button ...

Page 8: ...crew 4x50mm 4ea Video Amplifier Screw 3x8mm 4ea Rectifier 3x8mm 2ea Concealed Box KLP P100 KLP 100 Specifications of Tenkey Button Type Products KDP 100 Video phone connecting model L Le en ns s T Ty yp pe e P Pi in nh ho ol le e L Le en ns s T Ty yp pe e Doorphone connecting model KLP C100 KLP PC100 B W Color ...

Page 9: ...yphone From center of lens to bottom of flush mounting box 188mm Whole height of flush mounting box 224mm On the basis of the center of lobbyphone s lens 1 500 1 220 1 780 Unit mm Standard installation height of lobbyphone is 1 400 1 450mm from floor to the bottom of flush mounting box In case that the installation height of lobbyphone is out of the range min 1 250mm 1 550mm it s hard to get prope...

Page 10: ...For Multi Apartment or Villa Use it s Connection ...

Reviews: