background image

Product Specifications 

AC 220V - AC 230V / DC17V - DC20V (Stand-by: Min 4.1W, Operation: Max 24W)

DC +12.8V

Call Signal (Electronic Tone Sound)

User can monitor situations of front door camera using "Front Door" button on monitor.

By pressing "Guard/Lobby" button for about 5 seconds, users can monitor lobby situations

(This function is available only in lobby phones adopting TEN-KEY [KLP-100 series] mode).

When pressing call button on outdoor camera, call signal rings.

Explanation for melody type of front door camera :

- Camera 1 : ‘Ding-Dong~’ 2times

- Camera 2 : ‘Ddiriri~’ 8times

Hands-free System (DSP)

In calling from front door camera, image maintains for about 30 seconds. 

While communicating, image maintains for about 3 minutes.

Front Door Camera: 4-wire Polarity IV 0.65mm or more

Main line: VOICE1/VOICE2/DATA(3-line) Polarity IV 0.8mm or more

Power (+/GND) (2-line) Polarity IV 1.2mm or more

For Video line, coaxial cable is used - COAXIAL 5C-2V

191(W) X 217(H) X 52(D) mm

Front Door Camera: When 0.65mm cable is used, 30m

Main Line Communication Line: When IV 0.8

Ф

is used, 300m

Monitor: 0.C ~ 50.C

Power Source

Voltage of Operating Power

Lobby / Guardroom / In-house  Call Signal

Monitoring of Front Door Camera

Lobby Phone's Lobby 

Monitoring Function

Call Method

Communication Method

Image Maintenance Time

Number of Wiring

Dimensions

Communication Distance

Guaranteed Operation Temperature

��

KC-C63 Front Door Camera 

��

KIV-102 Monitor / KIV-D102 Monitor 

Component

Monitor Accessories

Camera 

Monitor Components

A Wall Hanger Frame

Wall Hanger 
Fixing Screws

Wiring Lines of Camera 1 & 2

Blue (Power)

Yellow (GND)

Red (Voice)

White (Video)

Gray (+17V)

Violet (GND)

Blue (Voice)

Green (Voice)

Yellow (Video)

Orange (Data)

Red (In-house Line)

Brown (Data in-house line)

Black (Video Output)

Wiring Lines of Multi-home Main Wiring

Front Door Camera Components

Camera Main Frame Supporter

Monitor

Screws for fixing camera 
to main frame supporter

Screws for fixing cabinet 
body on the wall

Upward adjusting Supporter
for lens angle

Power Source

Ambient temperature

Angle of picture

Min. Illumination

Lens

Dimension

DC12V

±

1V(Power supply for monitor)

-10

~ 50

Diagonal 120

0.1Lux(LED ON)

F:2.0,   f=3.0mm

95(W) X 127(H) X 34(D)mm

CAMERA (KC-C63)

Summary of Contents for KC-C63

Page 1: ...ity improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control a...

Page 2: ...e product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or quali...

Page 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can Hig...

Page 4: ...es should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of...

Page 5: ...ve minimizes temperature difference between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circul...

Page 6: ...tion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Wall hanger panel for fixing Monitor Scr...

Page 7: ...sed 30m Main Line Communication Line When IV 0 8 is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone...

Page 8: ...is not available to make conversation with front door camera 4 The DIP switch in sub unit should be set as 0 Cautions Door lock connection Only one door lock should be installed and connected to the m...

Page 9: ...door open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is dis...

Page 10: ...line button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call sig...

Page 11: ...t by DIP switches are summed up e g 1 Above figure turning switch No 1 and No 2 toward On direction value is set at 3 1 2 3 since numbers set by switches are 1 and 2 e g 2 Above figure turning switch...

Page 12: ...104 KLP 108 KLP 112 KLP C104 KLP C108 KLP C112 KLP P104 KLP P108 KLP P112 house KVM 520 and KIP 603 KIV 102 KIV D102 KIV 202 KIV D202 No setting should be conducted as following instructions A specif...

Reviews: