Kobold ZDM Series User Instructions Download Page 7

5

ZDM

FM Rev. 11/10

3.1.4

Connecting Piping to the Sensor

The procedure for attaching piping to the sensor depends on the type of 
thread that was ordered with the sensor. The most common thread in 
North America is NPT (series ZDM-3XXX and ZDM-4XXX sensors.) 
Occasionally, the European pipe thread (BSP) is ordered because of its 
superior leak resistance. Series ZDM-1XXX and ZDM-2XXX sensors all 
have BSP threaded fittings.

If the fittings on your ZDM are incorrect for your application, you can 
correct the situation by purchasing a different mounting plate.

3.1.4.1

If you have NPT threads, coat the threads with a paste type pipe 
sealant before threading into the mounting plate.

We recommend that PTFE tape NOT be used since pieces of it 
may find their way into the sensor, possibly causing the gears to 
bind. Should you have no alternative to PTFE tape, make sure that 
it is properly trimmed and does not extend beyond the first thread 
on your pipe fittings.

3.1.4.2

If you have BSP threads, place the sealing gaskets over the ends 
of your pipe fittings and thread fittings into the mounting plate.

3.2

Electrical Connections

The standard ZDM operates on a power supply of: 10-28 VDC.

Diagram 3.2.1: 

 ZDM Wiring Schematic

Summary of Contents for ZDM Series

Page 1: ...sitive Displacement Flow Meter User Instructions USA 1801 Parkway View Drive Pittsburgh PA 15205 PH 412 788 2830 Canada 9A Aviation Point Claire QC H9R 4Z2 PH 514 428 8090 www koboldusa com ZDM_manual...

Page 2: ...g Plate 4 3 1 3 Bolt Torque Specifications 4 3 1 4 Connecting Piping to the Sensor 5 3 2 Electrical Connections 5 4 0 Operating Instructions 6 4 1 Turning the Unit On 6 4 2 Flow Measurement 6 4 3 Turn...

Page 3: ...tation by the force of liquid moving past the gears along the meter s housing Engagement of the gear teeth with the housing walls entraps a defined volume in the cavity between the gear teeth A detect...

Page 4: ...port The resolution of the ZDM is therefore determined by the volume between the gear teeth This entire procedure is completely independent of the properties of the liquid making the system applicabl...

Page 5: ...F Accuracy 0 3 of reading with viscosity 20 cSt Repeatability 0 05 of reading Electrical Data Sensor Type Qty 2 Push Pull Outputs Channels A B A B Signals are 90 out of phase Phase difference can be...

Page 6: ...h use of the four threaded holes in the base of the mounting plate These holes are metric and sized as follows ZDM XX02 to ZDM XX08 M6 6 mm metric ZDM XX09 to ZDM XX40 M8 8 mm metric 3 1 2 Attaching t...

Page 7: ...ation by purchasing a different mounting plate 3 1 4 1 If you have NPT threads coat the threads with a paste type pipe sealant before threading into the mounting plate We recommend that PTFE tape NOT...

Page 8: ...pply voltage Vcc minus 1 0 VDC A representation of the waveform is given in Diagram 4 2 1 ZDM Frequency Output Waveform on page 6 Each pulse in the transmitted signal represents a fixed quantity of li...

Page 9: ...oning condition The frequency of filter replacement and maintenance will depend on the level on cleanliness of the metered liquid The only wear component in the ZDM are the gear teeth The gear teeth w...

Page 10: ...9 ZDM FM Rev 11 10 Appendix A Pressure Loss vs Flow Rate at Various Viscosities...

Page 11: ...ZDM 10 FM Rev 11 10...

Page 12: ...11 ZDM FM Rev 11 10...

Page 13: ...ZDM 12 FM Rev 11 10 ZDM 0010 Pressure Loss...

Page 14: ...13 ZDM FM Rev 11 10...

Page 15: ...v 11 10 CAUTION PLEASE READ THE FOLLOWING WARNINGS BEFORE ATTEMPTING INSTALLATION OF YOUR NEW DEVICE FAILURE TO HEED THE INFORMATION HEREIN MAY RESULT IN EQUIPMENT FAILURE AND POSSIBLE SUBSEQUENT PERS...

Page 16: ...designed for use in media temperatures from 40 to 248 F and for use at pressures up to 6500 PSIG depending on model Operation outside these limitations will cause damage to the unit and possible pers...

Reviews: