Kobold ZDM Series User Instructions Download Page 6

ZDM

4

FM Rev. 11/10

2.2.2

Pressure Loss

Pressure loss is a function of the viscosity of the liquid being metered, and 
its rate of flow. Detailed pressure loss information may be found in 
Appendix A of this manual.

3.0

Installation Instructions

CAUTION:

For safety reasons, please read the cautionary information located at 
the end of this manual, before attempting installation.

3.1

Mechanical Installation

The ZDM is shipped from the factory in two pieces (not counting the electrical 
connecting cable or the sensor-mounting plate fastening bolts) consisting of the 
mounting plate and the sensor body. We recommend that you install the mounting 
plate first, then attach the sensor and finally connect the piping.

3.1.1

Installing the Mounting Plate

The sensor may be rigidly held in place on your installation through use of 
the four threaded holes in the base of the mounting plate. These holes are 
metric and sized as follows:

ZDM-XX02 to ZDM-XX08:

M6 (6 mm metric)

ZDM-XX09 to ZDM-XX40:

M8 (8 mm metric)

3.1.2

Attaching the Flow Sensor to the Mounting Plate

The sensor comes supplied with a set of four steel bolts and O-rings for 
fastening the sensor to the mounting plate. 

3.1.2.1

Install the O-rings into the grooves in the body of the sensor.

3.1.2.2

Position the sensor on the mounting plate so that the bolt holes in 
the sensor line up with the bolt holes in the mounting plate.

3.1.2.3

Insert the bolts into the bolt holes and thread into mounting plate 
until they are finger tight.

3.1.2.4

With an appropriately sized wrench, tighten the bolts to the speci-
fied torque in a diagonal bolt tightening pattern.

3.1.3

Bolt Torque Specifications

The following are the nominal torque specifications for all ZDM bolts.

Meter Model

Torque (N-m)

Torque (lb.-ft.)

ZDM-XX02 to ZDM-XX08:40

29.5

ZDM-XX09 to ZDM-XX20:70

51.6

ZDM-XX40:

120

88.5

Summary of Contents for ZDM Series

Page 1: ...sitive Displacement Flow Meter User Instructions USA 1801 Parkway View Drive Pittsburgh PA 15205 PH 412 788 2830 Canada 9A Aviation Point Claire QC H9R 4Z2 PH 514 428 8090 www koboldusa com ZDM_manual...

Page 2: ...g Plate 4 3 1 3 Bolt Torque Specifications 4 3 1 4 Connecting Piping to the Sensor 5 3 2 Electrical Connections 5 4 0 Operating Instructions 6 4 1 Turning the Unit On 6 4 2 Flow Measurement 6 4 3 Turn...

Page 3: ...tation by the force of liquid moving past the gears along the meter s housing Engagement of the gear teeth with the housing walls entraps a defined volume in the cavity between the gear teeth A detect...

Page 4: ...port The resolution of the ZDM is therefore determined by the volume between the gear teeth This entire procedure is completely independent of the properties of the liquid making the system applicabl...

Page 5: ...F Accuracy 0 3 of reading with viscosity 20 cSt Repeatability 0 05 of reading Electrical Data Sensor Type Qty 2 Push Pull Outputs Channels A B A B Signals are 90 out of phase Phase difference can be...

Page 6: ...h use of the four threaded holes in the base of the mounting plate These holes are metric and sized as follows ZDM XX02 to ZDM XX08 M6 6 mm metric ZDM XX09 to ZDM XX40 M8 8 mm metric 3 1 2 Attaching t...

Page 7: ...ation by purchasing a different mounting plate 3 1 4 1 If you have NPT threads coat the threads with a paste type pipe sealant before threading into the mounting plate We recommend that PTFE tape NOT...

Page 8: ...pply voltage Vcc minus 1 0 VDC A representation of the waveform is given in Diagram 4 2 1 ZDM Frequency Output Waveform on page 6 Each pulse in the transmitted signal represents a fixed quantity of li...

Page 9: ...oning condition The frequency of filter replacement and maintenance will depend on the level on cleanliness of the metered liquid The only wear component in the ZDM are the gear teeth The gear teeth w...

Page 10: ...9 ZDM FM Rev 11 10 Appendix A Pressure Loss vs Flow Rate at Various Viscosities...

Page 11: ...ZDM 10 FM Rev 11 10...

Page 12: ...11 ZDM FM Rev 11 10...

Page 13: ...ZDM 12 FM Rev 11 10 ZDM 0010 Pressure Loss...

Page 14: ...13 ZDM FM Rev 11 10...

Page 15: ...v 11 10 CAUTION PLEASE READ THE FOLLOWING WARNINGS BEFORE ATTEMPTING INSTALLATION OF YOUR NEW DEVICE FAILURE TO HEED THE INFORMATION HEREIN MAY RESULT IN EQUIPMENT FAILURE AND POSSIBLE SUBSEQUENT PERS...

Page 16: ...designed for use in media temperatures from 40 to 248 F and for use at pressures up to 6500 PSIG depending on model Operation outside these limitations will cause damage to the unit and possible pers...

Reviews: