![Kobold VKG Operating Instructions Manual Download Page 18](http://html.mh-extra.com/html/kobold/vkg/vkg_operating-instructions-manual_1982520018.webp)
VKG
Page 18
VKG K09/0322
12. Ordering Codes
Viscosity-compensated flow meters model VKG-1…
(Example:
VKG-1103 R15
)
Measuring
range
l/min. oil
Pressure loss
P (bar)
at rated flow*
Brass
Stainless
steel
Contact
Connection
Option
Special
connection
min.
max.
0.1...0.45
0.6
0.9
VKG-1101...
VKG-1201...
...00...=
without contact
..R08=
G 1/4
..N08=
1/4 NPT
B
= outlet
fernelle
thread
inlet BVB
manifold
0.2...1.2
0.04
1.0
VKG-1102...
VKG-1202...
..R08=
G 1/4
..R15=
G 1/2
..N08=
1/4 NPT
..N15=
1/2 NPT
0.4...2
0.04
1.0
VKG-1103...
VKG-1203...
0.6...3.4
0.04
0.9
VKG-1104...
VKG-1204...
2...8
0.06
1.0
VKG-1105...
VKG-1205...
3...15
0.04
1.0
VKG-1106...
VKG-1206...
..R15=
G 1/2
..R20=
G 3/4
..N15=
1/2 NPT
..N20=
3/4 NPT
4...20
0.04
1.0
VKG-1107...
VKG-1207...
2,5...45
0.08
0.4
VKG-1108...
VKG-1208...
..R20=
G 3/4
..R25=
G 1
..N20=
3/4 NPT
..N25=
1 NPT
5...55
0.1
1.0
VKG-1109...
VKG-1209...
2.5...70
0.1
1.1
VKG-1110...
VKG-1210...
5...80
0.1
1.0
VKG-1111...
VKG-1211...
..R25=
G 1
..N25=
1 NPT
*The pressure loss is based on water.
Viscosity-compensated flow meters and switches model: VKG-2…
(Example:
VKG-2103 R15
)
Measuring
range
l/min. oil
Pressure loss
P (bar)
at rated flow*
Brass
Stainless
steel
Contact
Connection
Option
Special
connection
min.
max.
0.1...0.45
0.6
0.9
VKG-2101...
VKG-2201...
...R0...=
1 N/O contact
...U0...=
1 changeover
c.
...C0…
=1 N/O contact
(cCSAus)
...D0...
=1 changeover
c. (cCSAus)
...G0...
= 1 ATEX N/O
contact
(model 41R57)
...H0...
= 1 ATEX
changeover c.
(model 41R57U)
..R08=
G 1/4
..N08=
1/4 NPT
B
= outlet
fernelle
thread
inlet BVB
manifold
0.2...1.2
0.04
1.0
VKG-2102...
VKG-2202...
..R08=
G 1/4
..R15=
G 1/2
..N08=
1/4 NPT
..N15=
1/2 NPT
0.4...2
0.04
1.0
VKG-2103...
VKG-2203...
0.6...3.4
0.04
0.9
VKG-2104...
VKG-2204...
2...8
0.06
1.0
VKG-2105...
VKG-2205...
3...15
0.04
1.0
VKG-2106...
VKG-2206...
..R15=
G 1/2
..R20=
G 3/4
..N15=
1/2 NPT
..N20=
3/4 NPT
4...20
0.04
1.0
VKG-2107...
VKG-2207...
2,5...45
0.08
0.4
VKG-2108...
VKG-2208...
..R20=
G 3/4
..R25=
G 1
..N20=
3/4 NPT
..N25=
1 NPT
5...55
0.1
1.0
VKG-2109...
VKG-2209...
2.5...70
0.1
1.1
VKG-2110...
VKG-2210...
5...80
0.1
1.0
VKG-2111...
VKG-2211...
..R25=
G 1
..N25=
1 NPT
*The pressure loss is based on water.
Viscosity-compensated flow meters and switches with 2 contacts model: VKG-3…
(Example:
VKG-3103 R15
)
Measuring
range
l/min. oil
Pressure loss
P (bar)
at rated flow*
Brass
Stainless
steel
Contact
Connection
min.
max.
0.1...0.45
0.06
0.9
VKG-3101...
VKG-3201...
...RR...=1
N/O contact
...UU...=
1 changeover c.
...CC…
=1 N/O contact
(cCSAus)
...DD...
=1 changeover c.
(cCSAus)
...GG...
= 2 ATEX
N/O contact
(model 41R57)
...HH...
= 2 ATEX
changeover c.
(model 41R57U)
..R08=
G 1/4
..N08=
1/4 NPT
0.2...1.2
0.04
1.0
VKG-3102...
VKG-3202...
..R08=
G 1/4
..R15=
G 1/2
..N08=
1/4 NPT
..N15=
1/2 NPT
0.4...2
0.04
1.0
VKG-3103...
VKG-3203...
0.6...3.4
0.04
0.9
VKG-3104...
VKG-3204...
2...8
0.06
1.0
VKG-3105...
VKG-3205...
3...15
0.04
1.0
VKG-3106...
VKG-3206...
..R15=
G 1/2
..R20=
G 3/4
..N15=
1/2 NPT
..N20=
3/4 NPT
4...20
0.04
1.0
VKG-3107...
VKG-3207...
2,5...45
0.08
0.4
VKG-3108...
VKG-3208...
..R20=
G 3/4
..R25=
G 1
..N20=
3/4 NPT
..N25=
1 NPT
5...55
0.1
1.0
VKG-3109...
VKG-3209...
2.5...70
0.1
1.1
VKG-3110...
VKG-3210...
5...80
0.1
1.0
VKG-3111...
VKG-3211...
..R25=
G 1
..N25=
1 NPT
*The pressure loss is based on water.
Summary of Contents for VKG
Page 1: ...Operating Instruction for Viscosity Compensated Flow Meter and Monitor Model VKG ...
Page 8: ...VKG Page 8 VKG K09 0322 ...
Page 26: ...VKG Page 26 VKG K09 0322 ATEX not available in GB ...
Page 27: ...VKG VKG K09 0322 Page 27 ATEX not available in GB ...
Page 28: ...VKG Page 28 VKG K09 0322 ATEX not available in GB ...