2.4 General requirements
2.4.1 Intended Use
a) To ensure safe operation, the products may only be used according to the
instructions in the assembly instructions. During use, the legal and safety
regulations required for the respective application must be observed in
addition. This applies analogously when using accessories.
b) Failure to comply with the instructions given in this excerpt or in the case of
improper handling of the product will render our liability null and void. In
addition, the warranty on products and spare parts is void.
c) The products are not safety elements in terms of their intended use.
d) Only original parts of the manufacturer may be used.
2.4.2 General safety instructions
The reed switch corresponds to the state of the art and is reliable. The reed switch
may pose a residual hazard if improperly used and operated by untrained
personnel.
Every person, responsible for the installation, commissioning, maintenance or
repair of the reed switch, must have read and understood the assembly instructions
and in particular the safety instructions.
a)
Follow the general rules of technology for the selection and proper
operation of a product.
b)
All connected electrical and mechanical equipment must be suitable for
the respective application.
c)
Observe the notes in these operating instructions as well as the
conditions of use and permissible data that appear from the imprints /
nameplates of the respective products.
d)
It must be ensured that only product protection types corresponding to
the zones are installed!
e)
The product is only approved for proper and intended use in a normal
industrial atmosphere. Immersion in liquids is not permitted.
f)
It must be ensured that no falling objects can hit the product.
g)
The operator must ensure the lightning protection for the entire system in
accordance with local regulations.
h)
It is the responsibility of the installer to ensure that the function of the
reed switch in conjunction with the individual evaluation devices functions
properly and is approved for the intended use.
i)
The intrinsically safe connection - including the reed switches - must be
made via approved / tested evaluation devices, which may need to be
equipped with suitable zener barriers or switching amplifiers.
Summary of Contents for VKG
Page 1: ...Operating Instruction for Viscosity Compensated Flow Meter and Monitor Model VKG ...
Page 8: ...VKG Page 8 VKG K09 0322 ...
Page 26: ...VKG Page 26 VKG K09 0322 ATEX not available in GB ...
Page 27: ...VKG VKG K09 0322 Page 27 ATEX not available in GB ...
Page 28: ...VKG Page 28 VKG K09 0322 ATEX not available in GB ...