3. Instrument Inspection 

All Instruments are inspected before shipping and sent out in perfect condition.  
Should damage to a device be visible, we recommend a thorough inspection of 
the delivery packaging. In case of damage, please inform your parcel service / 
forwarding agent immediately, since they are responsible for damages during 
transit. 
 

Scope of delivery: 

The standard delivery includes: 

  Optical Level Sensor 

model: OPT 

 Operating instructions 

 
 
 

4. Regulation Use 

Any use of the Optical Level Sensor, model: OPT, which exceeds the 
manufacturers specification may invalidate its warranty. Therefore any resulting 
damage is not the responsibility of the manufacturer. The user assumes all risk 
for such usage. 
 
 
 

5. Operating Principle 

The optical level sensors of model OPT have been developed for monitoring 

transparent

 liquids. Due to the very small dimensions, very slight switching 

hysteresis and high repeatability, the instruments are also suited for service in 
small vessels. The optical sensor is situated in a robust housing. It comprises a 
plastic hollow hemisphere, in which the infrared diode is fitted as a transmitter 
and a semiconductor as a receiver. When the sensor is not wetted by liquid, the 
infrared light is reflected fully from the surface of the hemisphere to the receiver. 
As soon as the sensor is covered with liquid, the refractive index on the boundary 
layer changes and most of the light escapes into the liquid. Less light then 
reaches the receiver, which allows switching to take place. The level probe 
should not be fitted with the sensor pointing downwards, as errors can occur due 
to drops of liquid sticking to it. 
 
 
 

Summary of Contents for OPT Series

Page 1: ...Operating Instructions for Optical Level Sensor Model OPT...

Page 2: ...Fax 49 0 6192 23398 E mail info de kobold com Internet www kobold com 2 Note Please read these operating instructions before unpacking and putting the unit into operation Follow the instructions preci...

Page 3: ...Operating Principle The optical level sensors of model OPT have been developed for monitoring transparent liquids Due to the very small dimensions very slight switching hysteresis and high repeatabil...

Page 4: ...over In this position drops accumulating on the optical sensor can cause the sensor to report an apparent false simulated level switching point reached Recommended mounting positions On the side wall...

Page 5: ...l Connection 7 1 General Information Attention Make sure that the voltage values of your system correspond with the voltage values of the measuring unit Make sure that the supply wires are de energise...

Page 6: ...ng Power supply 5 12 VDC 5 Current input 15 mA typ at VDC without load Output NPN open collector function N O contact WET on Current output 10 mA max at 25 C 3 mA max at 80 C OPT 4 Power supply 24 VDC...

Page 7: ...sion Housing material Connection female thread OPT 0 5 12 VDC NPN OEM without CE 4 24 VDC 15 PNP 5 24 VDC 15 NPN 6 24 VDC 15 NPN 1 Polypropylene 2 Stainless steel 10 M14 with nut 22 G N4 NPT MSR 010 C...

Page 8: ...unity a EN 61000 4 4 2002 07 Susceptibility to fast transients IEC 1000 4 BURST b EN 61000 4 2 2001 12 Susceptibility to the discharge of electrostatic electricity EN 61000 6 3 2002 08 Electromagnetic...

Reviews: